Setup Center Application Installation Setup Verification and Traceability Activation 5.3.1 Installing 50 Installation Manual SIPLACE Setup Center 8.0 Step 7 Overview of the settings ► Here you will see the overview of th…

100%1 / 112
Setup Center Application Installation
5.3.1 Installing Setup Verification and Traceability Activation
Installation Manual SIPLACE Setup Center 8.0 49
Setup 5b Fill Level Control (2)
If the filling level correction should be allowed, activate the checkbox Operator may correct the filling
level. After that the operator may correct the filling level. Otherwise only the user with the right
"LineEngineer" and higher can correct the filling level.
Click Next to continue.
Step 6 Traceability
Here you can choose whether the Traceability Data should be created.
Furthermore you can select the File version 1.0 for standard TRC file or the File version 2.0 for ex
-
tended TRC file.
Click Next to continue. Wait until the next dialog box appears. It can be take a few minutes.
Setup Center Application Installation
Setup Verification and Traceability Activation 5.3.1 Installing
50 Installation Manual SIPLACE Setup Center 8.0
Step 7 Overview of the settings
Here you will see the overview of the settings.
Click Back to review or change the settings.
Click Next to continue the installation.
Step 8 Finishing the installation
Click Finish to end the installation.
Barcode-Scanner Installation
Safety Instructions
Installation Manual SIPLACE Setup Center 8.0 51
6
6 Barcode-Scanner Installation
Barcode-Scanner Installation
6.1
6.1 Safety Instructions
Safety Instructions
The Datalogic barcode scanners conforms to laser class 2.
Warning label W216 (shown above) is displayed on the Datalogic barcode scanner.
DANGER
LASER RADIATION!
Do not look into beam.
Laser class 2
WARNING
CAUTION:
Before using the Datalogic barcode scanner, inform all operating personnel about the laser reg
-
ulations.
While operating the Datalogic barcode scanner, observe the respective regulations in line with
VDE 0837 "Protection from radiation emitted by laser devices" and the "Laser radiation" acci
-
dent prevention regulations (VBG93), applicable in Germany.
Also observe the accident prevention regulations applicable in your country.
Despite the low laser power, avoid looking directly at the laser beam. The natural closure reflex
of your eyelids will protect your eyes from the visible beam.