00193463-01.pdf - 第41页

User Manual SIPLACE S-25 HM 1 Introduction, technical data Software Version SR.503.xx 04/2002 US Edition 1.13 Overview of the modules - placement heads 41 All the c ompone nts are inse rted with th e same cycle time . Be…

100%1 / 226
1 Introduction, technical data User Manual SIPLACE S-25 HM
1.13 Overview of the modules - placement heads Software Version SR.503.xx 04/2002 US Edition
40
1.13 Overview of the modules - placement heads
1.13.1 Structure of the 12-segment Collect&Place head
with standard component vision module
1
Fig. 1.13 - 1 Structure of the 12-segment Collect&Place head with standard component vision module
(1) Star with 12 sleeves (2) Motor for "Reject" valve adjustment drive
(3) Turning station (4) Component vision module
(5) Z-axis drive (6) Star motor
User Manual SIPLACE S-25 HM 1 Introduction, technical data
Software Version SR.503.xx 04/2002 US Edition 1.13 Overview of the modules - placement heads
41
All the components are inserted with the same cycle time. Before the component is inserted, it is
measured by the optoelectronic vision module. 1
The component vision camera creates an image of the current component.
The precise position of the component is also determined.
The package form of the current component is compared against the programmed package
form in order to identify it. Any components that cannot be identified are rejected.
The turning station turns the component to the required placement position.
1.13.2 Description of the 12-segment Collect&Place head
The 12-segment Collect&Place head works using the "collect & place" principle, i.e. the com-
ponents are held by the nozzles with the aid of a vacuum and, after one complete pick-up cycle,
are placed gently and accurately on the PCB with the aid of forced air. The vacuum in the noz-
zles is also checked several times to determine whether the components were picked up and
set down correctly.
The "adaptive" sensor stop mode of the z axis compensates for any irregularity of the PCB sur-
face when the components are set down.
Defective components are rejected and are picked up again during a repair run.
1.13.3 Technical data - 12-segment Collect&Place head
with standard component vision module
1
Range of components 0201 to PLCC44, including BGA, µBGA, flip-chip,
TSOP, QFP, PLCC, SO to SO32, DRAM
Component specification
Max. height
Min. lead pitch
Min. bump pitch
Min. ball/bump diameter
Min. dimensions
Max. dimensions
Max. weight
6 mm
0.5 mm
0.35 mm
0.2 mm
0.6 mm x 0.3 mm
18.7 mm x 18.7 mm
2 g
Maximum stroke of the Z axis 16 mm
Programmable set-down force 2.4 to 5.0 N
Max. placement rate 12,500 components/h
Nozzle types 9xx
Angular accuracy ± 0.70° / 4
σ
Placement accuracy ± 90 µm / 4 σ
1 Introduction, technical data User Manual SIPLACE S-25 HM
1.13 Overview of the modules - placement heads Software Version SR.503.xx 04/2002 US Edition
42
1.13.4 Structure of the 6-segment Collect&Place head
with standard component vision module
1
Fig. 1.13 - 2 Overview of the 6-segment Collect&Place head with standard component vision module
(1) Star with 6 sleeves
(2) Motor for "Reject" valve adjustment drive
(3) Turning station
(4) Standard vision module
(5) Z axis driving mechanism
(6) Star motor
1