00193463-01.pdf - 第79页

User Manual SIPLACE S-25 HM 2 Operational Safety Software Vers ion SR.503.xx 04/2002 US Edition 2.2 Safety equipment 79 2.2 Safe ty equip ment 2.2.1 Protective cover s 2 Fig. 2.2 - 1 SIPLACE S-23 HM safety equipment in t…

100%1 / 226
2 Operational Safety User Manual SIPLACE S-25 HM
2.1 Safety instructions Software Version SR.503.xx 04/2002 US Edition
78
WARNING 2
Æ NEVER place your hand in the gaps between the matrix tray changer and machine frame
(item 1) while the machine is running.
Æ Always couple the matrix tray changer to the machine before connecting or disconnecting the
matrix tray changer control cable at the machine socket (item 2).
Æ Always couple the matrix tray changer to the machine before connecting or disconnecting the
control cable for the matrix tray changer’s integral component feeder table at the machine
socket (item 3).
Æ Always couple the matrix tray changer to the machine before connecting or disconnecting the
power cable from the external power supply (item 4).
Æ NEVER operate the matrix tray changer if it is not coupled to the machine.
User Manual SIPLACE S-25 HM 2 Operational Safety
Software Version SR.503.xx 04/2002 US Edition 2.2 Safety equipment
79
2.2 Safety equipment
2.2.1 Protective covers
2
Fig. 2.2 - 1 SIPLACE S-23 HM safety equipment in the placement machine
Key to Fig. 2.2 - 1
(1) Cover and guard on the input belt
(2) Safety panels, righthand side
(3) Protective cover
(4) Cover and guard on the output conveyor
(5) Protective cover
(6) Safety panels, lefthand side
2 Operational Safety User Manual SIPLACE S-25 HM
2.2 Safety equipment Software Version SR.503.xx 04/2002 US Edition
80
2.2.1.1 General
The gantry positioning range is covered by two protective covers. If you want to open the protec-
tive covers, first press the Stop button (item 1 in Fig. 2.2 - 2) or the emergency stop mushroom-
head push-button (item 2 in Fig. 2.2 - 2). The power to the gantry axes will be switched off and the
gantries will stop immediately. 2
If you open one of the protective covers or a guard on the incoming or outgoing conveyor, the
power to the gantry axes will be switched off and they will stop immediately. 2
If the key switch is closed (position I), you can continue to pace the star at reduced speed while
the protective covers are open. 2
Placement will stop if you press the emergency stop button. You can then either cancel or continue
placement of the PCB. The protective covers at the sides can be opened in order to refill with com-
ponents when the machine has stopped. 2
WARNING
The protective covers must only be opened, with the key switch closed (position I), by appropri-
ately qualified and trained personnel. 2
Fig. 2.2 - 2 Stop and emergency stop mushroom-head push-buttons
(1) Stop button
(2) EMERGENCY STOP mushroom-head push-button