User Manual SIPLACE S-25 HM 2 Operational Safety Software Vers ion SR.503.xx 04/2002 US Edition 2. 3 Residual voltages in the servo unit and discharge t imes 89 2.3.1 O perating vol tages, re sidual volt ag es and discha…

2 Operational Safety User Manual SIPLACE S-25 HM
2.3 Residual voltages in the servo unit and discharge times Software Version SR.503.xx 04/2002 US Edition
88
2.3 Residual voltages in the servo unit and discharge
times
When the emergency stop mushroom-head push-button is pressed or the placement system is
switched off, the electrolytic capacitors quickly discharge to safe residual voltage levels via
switched resistors on the discharge board (00308443-xx).
The voltages can be tapped off at test sockets 001 - 009 on the voltmeter unit in the servo unit.2
DANGER Automatic placement systems from the SIPLACE family are
powered with 3 x 400 VAC (3 x 208 VAC for the U.S.A. version) ± 5 %, 50/60 Hz main power volt-
age. This means that parts of the system carry potentially fatal voltages - even when switched off
at the main switch.
Death, serious injury or considerable damage may result if these placement systems are handled
incorrectly. Always follow the applicable accident prevention and DIN regulations (particularly
EN 60204, part 1).
The guard over the servo unit must ONLY be opened by appropriately qualified and trained per-
sonnel. 2
Fig. 2.3 - 1 Test sockets on the voltmeter unit in the servo unit
GND
007
001 002 003 004 005 006
008 009
70VDC/
10VDC
30VDC 24VDC 12VDC 5VDC
70VDC
155VDC/0VDC
30VDC
un-
switched
switched
Servo
unit

User Manual SIPLACE S-25 HM 2 Operational Safety
Software Version SR.503.xx 04/2002 US Edition 2.3 Residual voltages in the servo unit and discharge times
89
2.3.1 Operating voltages, residual voltages and discharge times after pressing
the emergency stop mushroom-head push-button
2
2.3.2 Residual voltages and discharge times after switching off at the main switch
2
CAUTION To avoid losing data, evaluate the following criteria before switching off your
automatic placement system (apart from in emergencies):
– Has the placement system finished transmitting machine, set-up and working data?
– Has the placement system finished processing the PCB?
– Has the placement system completed the run-up phase?
– Has the Windows NT operating system been shut down correctly? 2
Test socket 00X
measured at 007
(GND)
Voltage
in normal mode
Residual voltage
after emerg. stop
Discharge times
of electrolytic
capacitors at 12 VDC
001 70 VDC 10 VDC < 2 sec
002 30 VDC 30 VDC –
003 30 VDC < 12 VDC < 2 sec
004 24 VDC 24 VDC –
005 12 VDC 12 VDC –
006 5 VDC 5 VDC –
008 70 VDC 10 VDC < 2 sec
009 155 VDC 10 VDC < 1 sec
Tab. 2.3 - 1 Operating voltages, residual voltages and discharge times after pressing the emergency stop
mushroom-head push-button
Test socket 00X
measured at 007 (GND)
Residual voltage
when main switch is off
Discharge times of electrolytic
capacitors at 12 VDC
001 < 12 VDC < 2 sec
002 < 12 VDC < 2 sec
003 < 12 VDC < 2 sec
004 0 VDC –
005 0 VDC –
006 0 VDC –
008 < 12 VDC < 2 sec
009 < 12 VDC < 1 sec
Tab. 2.3 - 2 Residual voltages and discharge times after switching off at the main switch

2 Operational Safety User Manual SIPLACE S-25 HM
2.4 Disabling the compressed air supply and discharging the pressure Software Version SR.503.xx 04/2002 US Edition
90
2.4 Disabling the compressed air supply and discharg-
ing the pressure
The compressed air working pressure is set to 5.1 bar, although it may fluctuate between 5.0 and
5.3 bar. The position of the compressed air unit is indicated by item 5 in Fig. 2.4 - 1. The com-
pressed air supply to the machine can be interrupted using the shut-off valve (item 1 in
Fig. 2.4 - 1). 2
– You must remove the cover plate to use the shut-off valve.
– Turn the lever on the shut-off valve (item 1 in Fig. 2.4 - 1) from the vertical to the horizontal
position.
– Watch the working pressure gauge (item 2 in Fig. 2.4 - 1) and the pressure gauge for the com-
pressed air supply to the stopper (item 4 in Fig. 2.4 - 1). When the automatic placement system
is switched on, the pressure discharges to 0 bar within 1 minute.
Fig. 2.4 - 1 Compressed air unit on the automatic placement system
WARNING Never disconnect compressed air lines while they are pressurized. 2
(1) Shut-off valve lever in the CLOSED position
(2) Working pressure gauge
(3) Solenoid valve for venting the tape cutter during an emergency stop
(4) Pressure gauge for the PCB stopper working pressure
(5) Compressed air supply, gantry 2
(6) Compressed air supply, gantry 1
(7) Position of the compressed air unit