2 Assembly instructions Special design Cognex Scanner SI PLACE HS-60 / HF-series / X-ser ies / D-series / S / F 06/2008 Edition 32 2.3 Restrictions – The PCB barcode has to be placed on the firs t 15-22 cm of the PCB. Th…

100%1 / 54
2 Assembly instructions Special design Cognex Scanner SIPLACE HS-60 / HF-series / X-series / D-series / S / F
06/2008 Edition
31
2 Assembly instructions
Special design Cognex Scanner
SIPLACE HS-60 / HF-series / X-series
/ D-series / S / F
2.1 Functional principle
The Cognex scanner enables to scan the 2D barcode on the PCB and sends it to the conveyor
control unit for evaluation. 2
2.2 Requirements
For SIPLACE HS-50: 2
Mounting set for PCB barcode scanner HS-60 (Item no.: 00119330-01) 2
For SIPLACE HS-60 / D1 / D2 / D4: 2
Mounting set for PCB barcode scanner HS-60 (Item no.: 00119430-01) 2
For SIPLACE HF-series / X-series / D3: 2
Mounting set for PCB barcode scanner HF (Item no.: 00119648-01) 2
For SIPLACE S / F: 2
Mounting set for PCB barcode scanner S / F (Item no.: 00118530-01) 2
2 Assembly instructions Special design Cognex Scanner SIPLACE HS-60 / HF-series / X-series / D-series / S / F
06/2008 Edition
32
2.3 Restrictions
The PCB barcode has to be placed on the first 15-22 cm of the PCB. The maximum scanning
range is arround 22 cm depending on the set scanning frequency.
The barcode should have the same size.
The exposure time has to be set up by the operator software of the scanner.
The upper barcode has to be placed at least 3 mm from the side edge of the PCB.
The lower barcode has to be placed at least 5 mm from the side edge of the PCB.
Only the barcode on one side can be scanned at once.
The common restrictions for PCB barcodes at SIPLACE machines still apply.
2 Assembly instructions Special design Cognex Scanner SIPLACE HS-60 / HF-series / X-series / D-series / S / F
06/2008 Edition
33
2.4 Scope of delivery
General: 2
Dataman I/O Box from Cognex (00176118-xx)
Adapter cable for Dataman 100 I/O Box
Assembly instructions for Cognex Scanner (item no.: 00195610-xx)
Soko CD with documentation, Dataman data sheet and Cognex software
2
For one scanner: 2
1 Cognex scanner Dataman 100
1 Interface cable for Dataman 100 (03062979-xx)
1 Holding bracket for scanner – upper side – premounted
or
1 holding bracket for scanner – lower side – premounted
2 Hexagon socket screws M3 x 5 mm
2 Washers ø 7,0 mm
2
For two scanners: 2
2 Cognex scanner Dataman 100
2 Interface cables for Dataman 100 (03062979-xx)
1 (2) Holding bracket(s) for scanner – upper side – premounted
and/or
1 (2) holding bracket for scanner – lower side – premounted
4 Hexagon socket screws M3 x 5mm
4 Washers ø 7,0 mm
2