2 Assembly instructions Special design Cognex Scanner SI PLACE HS-60 / HF-series / X-ser ies / D-series / S / F 06/2008 Edition 32 2.3 Restrictions – The PCB barcode has to be placed on the firs t 15-22 cm of the PCB. Th…
2 Assembly instructions Special design Cognex Scanner SIPLACE HS-60 / HF-series / X-series / D-series / S / F
06/2008 Edition
31
2 Assembly instructions
Special design Cognex Scanner
SIPLACE HS-60 / HF-series / X-series
/ D-series / S / F
2.1 Functional principle
The Cognex scanner enables to scan the 2D barcode on the PCB and sends it to the conveyor
control unit for evaluation. 2
2.2 Requirements
For SIPLACE HS-50: 2
Mounting set for PCB barcode scanner HS-60 (Item no.: 00119330-01) 2
For SIPLACE HS-60 / D1 / D2 / D4: 2
Mounting set for PCB barcode scanner HS-60 (Item no.: 00119430-01) 2
For SIPLACE HF-series / X-series / D3: 2
Mounting set for PCB barcode scanner HF (Item no.: 00119648-01) 2
For SIPLACE S / F: 2
Mounting set for PCB barcode scanner S / F (Item no.: 00118530-01) 2
2 Assembly instructions Special design Cognex Scanner SIPLACE HS-60 / HF-series / X-series / D-series / S / F
06/2008 Edition
32
2.3 Restrictions
– The PCB barcode has to be placed on the first 15-22 cm of the PCB. The maximum scanning
range is arround 22 cm depending on the set scanning frequency.
– The barcode should have the same size.
– The exposure time has to be set up by the operator software of the scanner.
– The upper barcode has to be placed at least 3 mm from the side edge of the PCB.
– The lower barcode has to be placed at least 5 mm from the side edge of the PCB.
– Only the barcode on one side can be scanned at once.
– The common restrictions for PCB barcodes at SIPLACE machines still apply.
2 Assembly instructions Special design Cognex Scanner SIPLACE HS-60 / HF-series / X-series / D-series / S / F
06/2008 Edition
33
2.4 Scope of delivery
General: 2
– Dataman I/O Box from Cognex (00176118-xx)
– Adapter cable for Dataman 100 I/O Box
– Assembly instructions for Cognex Scanner (item no.: 00195610-xx)
– Soko CD with documentation, Dataman data sheet and Cognex software
2
For one scanner: 2
– 1 Cognex scanner Dataman 100
– 1 Interface cable for Dataman 100 (03062979-xx)
– 1 Holding bracket for scanner – upper side – premounted
or
1 holding bracket for scanner – lower side – premounted
– 2 Hexagon socket screws M3 x 5 mm
– 2 Washers ø 7,0 mm
2
For two scanners: 2
– 2 Cognex scanner Dataman 100
– 2 Interface cables for Dataman 100 (03062979-xx)
– 1 (2) Holding bracket(s) for scanner – upper side – premounted
and/or
1 (2) holding bracket for scanner – lower side – premounted
– 4 Hexagon socket screws M3 x 5mm
– 4 Washers ø 7,0 mm
2