17 WF2 SX1/2 Check the cover fans and clean the protection cover. 1 min 1 / 1
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status ON Transport Empty
NOTICE! ESD guidelines are to be followed Tool:
T1
Wear Part: Consumables:
C1
www.asm-smt.com
1 Remove the protection cover. 2 Check the function of the cover fans. 3 Clean the protection cover.
4 Return the protection cover. 5 Repeat all steps for the other covers.
www.asm-smt.com
18 WF2 SX1/2 Appendix: C&P20x head exchange 3 min 1 / 6
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status OFF Transport Empty
NOTICE! ESD guidelines are to be followed Tool:
T49, T85, T94, K01
Wear Part: Consumables:
www.asm-smt.com
1 Move the gantry with the head to be main-
tained to the end limit.
2 Put on the corresponding component
sensor protection.
3 Unplug the 3 air hoses from the head.
4 Remove the protection cover. 5 Disconnect both ribbon cables. 6 Disconnect the pressure sensor (vacuum
pump only).