22 WF2 SX 1/2 - Appendix: Calibrate the TwinHead 8 min 6 / 9 C A U T I O N ! R e f e r t o s a f e t y i n s t r u c t i o n s i n u s e r m a n u a l b e f o r e c o m m e n c i n g M a i n t e n a n c e Machine Statu…

22 WF2 SX 1/2 - Appendix: Calibrate the TwinHead 8 min 5 / 9
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status ON Conveyor Empty
NOTICE! ESD guidelines are to be followed Tool:
K01
Wear Part: Consumables:
www.asm-smt.com
25 Repeat this steps for all magazines. 26 Configure both garages in magazine 2
with nozzle 517.
27 Configure both garages in magazine 3
with nozzle 518.
28 Click on "Close" to take over the configur-
ation.
29 Click on "Check and set configuration of
nozzles on head".
30 Click on "All nozzles" and "Change with".

22 WF2 SX 1/2 - Appendix: Calibrate the TwinHead 8 min 6 / 9
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status ON Conveyor Empty
NOTICE! ESD guidelines are to be followed Tool:
K01
Wear Part: Consumables:
www.asm-smt.com
31 Click on "Calibration nozzle 517" and
"OK".
32 Click on "Move in all component tables". 33 Press the start button.
34 Click on "Configure, update and calibrate
the machine".
35 Click on "Automatic calibration". 36 Select "Calibration of fiducials, cameras
and head".

22 WF2 SX 1/2 - Appendix: Calibrate the TwinHead 8 min 7 / 9
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status ON Conveyor Empty
NOTICE! ESD guidelines are to be followed Tool:
K01
Wear Part: Consumables:
www.asm-smt.com
37 Select the gantry with the head to be calib-
rated and click on "Next".
38 Click on "Start ". 39 Click on "Start".