00197815-04_JC_PM_WF2_SX12_EN.pdf - 第59页
19 WF2 SX1/2 Appendix: CPP head exchange 3 min 1 / 4 C A U T I O N ! R e f e r t o s a f e t y i n s t r u c t i o n s i n u s e r m a n u a l b e f o r e c o m m e n c i n g M a i n t e n a n c e Machine Status OFF Tr…

18 WF2 SX1/2 Appendix: C&P20x head exchange 3 min 6 / 6
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status OFF Transport Empty
NOTICE! ESD guidelines are to be followed Tool:
T49, T85, T94, K01
Wear Part: Consumables:
www.asm-smt.com
31 Mount the protection cover. 32 Connect the 3 air hoses. 33 Move the gantry with the maintained head
to the end limit.
34 Remove the component sensor protection. 35 Proceed with task “Clean the Z-Axis of the
remaining C&P20x”.

19 WF2 SX1/2 Appendix: CPP head exchange 3 min 1 / 4
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status OFF Transport Empty
NOTICE! ESD guidelines are to be followed Tool:
T58, K01
Wear Part: Consumables:
www.asm-smt.com
1 Move the gantry with the head to be main-
tained to the end limit.
2 Put on the corresponding component
sensor protection.
3 Unplug the 3 air hoses from the head.
4 Disconnect both ribbon cables. 5 Loosen the screws holding the strain relief
(HotLink only).
6 Unplug both camera cables (HotLink only).

19 WF2 SX1/2 Appendix: CPP head exchange 3 min 2 / 4
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status OFF Transport Empty
NOTICE! ESD guidelines are to be followed Tool:
T58, K01
Wear Part: Consumables:
www.asm-smt.com
7 Open the camera cable clip (GigE only). 8 Release the plug lock and unplug the two
camera cables (GigE only).
9 Loosen the 4 screws fixing the head.
10 Take the head from the hook. 11 Put the head into the transport container. 12 Take the maintained head out of transport
container.