00197815-04_JC_PM_WF2_SX12_EN.pdf - 第53页

18 WF2 SX1/2 Appendix: C&P20x head exchange 3 min 1 / 6 C A U T I O N !  R e f e r t o s a f e t y i n s t r u c t i o n s i n u s e r m a n u a l b e f o r e c o m m e n c i n g M a i n t e n a n c e Machine Status…

100%1 / 86
www.asm-smt.com
18 WF2 SX1/2 Appendix: C&P20x head exchange 3 min 1 / 6
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status OFF Transport Empty
NOTICE! ESD guidelines are to be followed Tool:
T49, T85, T94, K01
Wear Part: Consumables:
www.asm-smt.com
1 Move the gantry with the head to be main-
tained to the end limit.
2 Put on the corresponding component
sensor protection.
3 Unplug the 3 air hoses from the head.
4 Remove the protection cover. 5 Disconnect both ribbon cables. 6 Disconnect the pressure sensor (vacuum
pump only).
18 WF2 SX1/2 Appendix: C&P20x head exchange 3 min 2 / 6
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status OFF Transport Empty
NOTICE! ESD guidelines are to be followed Tool:
T49, T85, T94, K01
Wear Part: Consumables:
www.asm-smt.com
7 Loosen the screws holding the strain relief
(HotLink only).
8 Unplug both camera cables (HotLink only). 9 Release the plug lock and unplug the two
camera cables (GigE only).
10 Open the camera cable clip (GigE only). 11 Loosen the 2 screws on the pressure reg-
ulator valve (C&P20 A only).
12 Loosen the 4 screws fixing the head.