Nordson_EFD_OptiSure_Operating_Manual.pdf - 第49页
OptiSure Automated Optical Inspection 49 www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide. Using the Arr ow T ypes (continued) # Click Ste…

OptiSure Automated Optical Inspection
48 www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
Mea. Width Example for Verifying Line Width
Mea. Width (Measure Width) is an OptiSureAOI feature that can be used in tandem with the Arrow Check Point or
Arrow Check Line commands to measure the width of a predefined line, compare that measurement to subsequent
dispenses (for either one section of the line or the complete line), and then, depending on the user-specified
parameters, determine if the dispense is acceptable. If the dispense does not meet the specified criteria, the system
takes the action specified in the Arrow Check Point or Arrow Check Line command.
PREREQUISITES
To learn how to use this feature, draw a line on a sheet of white paper and use it as a workpiece template.
To Create a Mark Image for the Desired Line Dispense
# Click Step Reference Image
1
>
>
• Jog the camera to a location near the
beginning of the line.
• Click SET MARK, then drag to position
the red box over the line.
2
>
• Click a socket in the Mark Library to
save the mark, then click TEMPLATE
when the Template Match window
appears.
The system saves the image in the
Mark Library.
3
>
• Click the ARROW icon.
• In the Primary View screen, right-click
and select ADD NEW ARROW.
The system adds an arrow to the
screen.
Continued on next page
Using the Arrow Types (continued)

OptiSure Automated Optical Inspection
49www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
Using the Arrow Types (continued)
# Click Step Reference Image
4
1.
2.
3.
• Use the mouse to drag the arrow to
the line:
- To move the entire arrow, click and
drag the middle box (item 1).
- To elongate or shorten the arrow,
click and drag the arrow point
(item2) or the upper box (item 3).
5
4.
• Right-click the middle box (item4)
of the arrow and then select
PARAMETER.
The AOI Arrow window opens.
6 • For Type, select MEA. WIDTH.
7 • Select LIGHT TO DARK.
• Adjust PIXEL AVG to make the mark
image easier for the system to find.
• Check CENTER if you want to center
the image based on the image in the
mark library.
• For MAX, enter the maximum
allowable width of the line. The
displayed AVG (average) value is equal
to the line width.
• For MIN, enter the minimum allowable
width of the line.
Continued on next page
Mea. Width Example for Verifying Line Width (continued)
To Create a Mark Image for the Desired Line Dispense (continued)

OptiSure Automated Optical Inspection
50 www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
Using the Arrow Types (continued)
Mea. Width Example for Verifying Line Width (continued)
To Create a Mark Image for the Desired Line Dispense (continued)
# Click Step Reference Image
8
• Adjust THRESHOLD until the two small
red circles (item 5) are positioned on
the top and bottom edges of the line.
• Close the dialog box to save the
settings.
5.
5.
The saved mark image is now ready to be used in a program to check the
width of a dispensed line:
- If you want the system to check the width of a complete line, use Arrow
Check Line. Continue to “To Use Arrow Check Line in a Program (Mea.
Width Example for Verifying Line Width)” on page51.
- If you want the system to check the width of a section of line, use Arrow
Check Point. Continue to “To Use Arrow Check Point in a Program
(Mea. Width Example for Verifying Line Width)” on page52.