Nordson_EFD_OptiSure_Operating_Manual.pdf - 第7页

OptiSure Automated Optical Inspection 7 www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide. Enter the Access Code # Click Step Reference Ima…

100%1 / 76
OptiSure Automated Optical Inspection
6 www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
Enabling the OptiSureAOI Feature
Two important actions are required to use the full functionality of the OptiSureAOI add-on:
An access code must be used to unlock the OptiSureAOI add-on. To obtain the access code, you must
provide the Dongle Serial No. to Nordson EFD as described in this section.
For some OptiSureAOI features to function properly, a script file must be present on the DispenseMotion
controller. Obtain this script file from your Nordson representative.
NOTE: If you have not purchased the OptiSureAOI software key, refer to “OptiSureAOI Kit Part Numbers” on
page70 for the kit part numbers. Contact your Nordson EFD representative for assistance.
PREREQUISITES
The complete automated dispensing system is properly installed and set up in accordance with the respective
system’s operating manual.
You have purchased your OptiSureAOI kit(s).
You have obtained the main.bas file from your Nordson EFD representative.
If purchased, the optional confocal laser is installed in accordance with the installation instructions.
The DispenseMotion software is open.
Obtain the Access Code
#
Click Step Reference Image
1
> >
Click SYSTEM SETUP > OPEN > EXPERT.
2
11111111 >
Enter 11111111, then click OK.
3 Click FUNCTION CONTROL.
The Software Function Control Dialog
window opens.
4 xxxx xxxx xxxx xxxx >
>
Make a note of the Dongle Serial No., or
obtain a screen capture of the number.
Close the dialog box and click EXIT.
5 Provide the Dongle Serial No. number to
your Nordson EFD representative.
Nordson EFD will provide an Access Code.
When you receive the code, continue to
“Enter the Access Code” on page7.
OptiSure Automated Optical Inspection
7www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
Enter the Access Code
#
Click Step Reference Image
1
> >
Click SYSTEM SETUP > OPEN > EXPERT.
2
11111111 >
Enter 11111111, then click OK.
3 Click FUNCTION CONTROL.
The Software Function Control Dialog
window opens.
4 xxxx xxxx xxxx xxxx >
> >
Enter the ACCESS CODE and click
UNLOCK.
Close the dialog box and click EXIT.
5 Continue to “Add the Script File to the
DispenseMotion Controller” on page8.
Enabling the OptiSureAOI Feature (continued)
OptiSure Automated Optical Inspection
8 www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
Add the Script File to the DispenseMotion Controller
NOTE: The main.bas script file is not required for all OptiSureAOI functions, but Nordson EFD recommends adding
it to the DispenseMotion controller as a best practice.
#
Click Step Reference Image
1
If you have not already done so, contact
your Nordson EFD representative to obtain
the main.bas script file.
Place the main.bas file on a USB drive.
Insert the USB drive into an empty USB
port on the back of the DispenseMotion
controller.
NOTE: On most controllers, USB-3 is an
unused USB port.
2 Switch ON the DispenseMotion controller.
NOTE: Do not open the DispenseMotion
software at this time.
3
Using the file explorer application, navigate
to the USB drive and copy the main.bas
file.
Navigate to the D:\ever_sr directory and
paste the main.bas file into the directory.
4 Close the file explorer application.
The OptiSureAOI add-on is now unlocked
and ready for use. Refer to the remaining
sections of this manual for detailed
procedures for using the OptiSureAOI
features.
If you also installed the confocal laser,
continue to “Setting Up the Confocal
Laser” on page10.
Enabling the OptiSureAOI Feature (continued)