Nordson_EFD_OptiSure_Operating_Manual.pdf - 第70页
OptiSure Automated Optical Inspection 70 www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide. OptiSur eAOI Kit Part Numbers Nordson EFD’s Op…

OptiSure Automated Optical Inspection
69www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
Using the Laser to Measure and Record Profiles
(continued)
System Responses for Laser Threshold Measurement Checks
Action Reference Image
When SKIP is selected:
• If a measurement is outside a Max or Min
value, the program stops running after the
laser measurement is done and then prompts
to go to the HOME position. When this
occurs, click HOME.
When STOP is selected:
• If a measurement is below the Min value,
the program stops running and the system
generates a Surface Detect Fail warning.
When this occurs, click OK and then click
HOME.
• If a measured value is above the Max value,
the program stops running and the system
prompts to go to the HOME position. When
this occurs, click HOME.
When PAUSE is selected:
If a measurement is outside a Max or Min value,
the program stops running:
• Select CONTINUE to continue
running the program.
OR
• Select STOP to stop the program,
then click HOME to return the robot to the
HOME position.

OptiSure Automated Optical Inspection
70 www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
OptiSureAOI Kit Part Numbers
Nordson EFD’s OptiSure Automated Optical Inspection (AOI) software is available within the current DispenseMotion
software as an optional add-on. The AOI feature inspects fluid deposit widths and diameters with exceptional
certainty and determines if dispense requirements have been met. When paired with the OptiSureAOI confocal
laser, the AOI feature provides three-dimensional (3D) deposit verification by measuring the height, width, and
diameter of a fluid deposit and comparing it to a 3D image of a desired deposit to determine true volume accuracy.
The OptiSureAOI feature also includes advanced functions for augmenting mark images to make them easier for
the system find.
Item Part # Description
7365229 Software key, OptiSure Automated Optical Inspection (AOI)
7364992
Laser C accessory kit (includes the confocal laser and laser controller)
NOTES:
• For use only with the OptiSure AOI add-on
• Includes the OptiSure AOI software key
• Takes the place of Laser A or Laser B

OptiSure Automated Optical Inspection
71www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
AppendixA, Command Function Reference
This appendix provides detailed information for each setup and dispense command. Commands are in alphabetical
order.
The following rules apply to all commands:
• A command is in effect until it is superseded by another command.
• Command settings override system settings.
Arrow Check Point
Click Function
Double-click
address and
select from drop-
down menu
Used in tandem with the Mea. Width, Mea. Point to Line, and Positional Checking options of the
OptiSureAOI feature to check the width of a section of a dispensed line (between two specified points)
against a saved mark image that can specify Max and Min parameters for line width; if the width of a section
of dispensed line is not within the allowable range, the system takes the action specified by the Skip, Stop,
Pause, or Ask parameter.
Parameter Description
No. The number of the mark image saved for the line section.
0.Stop, 1.Skip,
2.Pause, 3.Ask
The action the system takes if a dispensed line section does not meet the parameters
specified for the saved mark image.
0.Stop The system stops running the program and displays an Arrow Check Fail
warning: Click OK to acknowledge the warning, then click HOME to move the
Zaxis to the Home position (0, 0, 0).
1.Skip The system skips the dispense and goes to the next command in the program.
2.Pause The system stops running the program and displays a “Waiting [Start] Button]”
box: Click START or CONTINUE to continue running the program; click STOP
and then HOME to stop the program and send the robot to the Home position
(0, 0, 0).
3.Ask The system stops running the program and displays a “Find Again, Find Next,
or Stop Find” box: Click FIND AGAIN to make the system check the point
again. Click FIND NEXT to go to the next command in the program. Click STOP
FIND to stop the program.