Periodic maintenance items
1. Weekly or biweekly inspection
Inspect and clean the nozzles weekly or biweekly as explained below.
1.1 Cleaning "Type A" nozzles
If solder adheres to a nozzle tip, the nozzle may be mistaken for a component or other problems may occur. If
nozzle spring-action is poor, pickup errors tend to occur frequently. To prevent these troubles, check the nozzle
condition and keep the nozzles clean.
e
1
Remove the nozzle from the head.
Always first press the emergency stop button
and then remove the nozzle from the head.
The machine must be in emergency stop to
ensure safety during work.
c
CAUTION
When the machine is equipped with a nozzle station,
make sure that the nozzles are returned to the nozzle
station after cleaning.
2
Blow air through the nozzle.
Using an air blow gun, blow air through the
nozzle from the nozzle tip and then from the
other end.
53300-F9-00
n
NOTE
If there are dust deposits in the nozzle, perform steps 3
and 4.
3
Clean the nozzle hole.
Pass the nozzle cleaning wire through the
nozzle hole and clean the nozzle hole. While
holding both ends of the wire with fingers as
shown or using a custom handle (option),
gently move the nozzle back and forth.
53301-F9-00
4
Blow air onto the nozzle tip again.
After removing the cleaning wire, blow air
through the nozzle with the air blow gun, just
as in step 2.
53302-F9-00
5
Clean the slide section.
Apply IPA (isoprophyl alcohol) or ethanol to
the slide section. Push the nozzle tip several
times to repeat the buffing action (spring
action) to clean the slide section. After
cleaning, blow sufficient air to remove IPA or
ethanol.
Cleaning a nozzle
Step 3
Custom
handle
(option)
Nozzle
Nozzle cleaning wire
Air blow
Step 4
NozzleAir blow gun (option)
Step 2
Air tube (black)
Air blow gun
(option)
Air tube (orange) connected to
air supply port
Air blow
Insert the
nozzle tip into
the air tube and
blow air.
Blow air from the
nozzle attachment
side.

3-2
3
Periodic maintenance items
6
Lubricate the slide section.
Using a precision screwdriver or similar tool
with a pointed tip, apply a small amount of
turbine oil (just enough so that it sinks in) to
the slide section.
53303-F9-10
7
Check the buffing action (spring
action).
Push the nozzle tip several times to repeat
the buffing action and spread turbine oil.
Use a lint-free cleaning cloth to wipe away
excess oil from around the nozzle.
53304-F9-10
8
Remove excess oil remaining in the
nozzle.
Using an air blow gun, blow air for about 5
seconds from the nozzle tip, and for about 5
seconds from the nozzle attachment side.
Repeat this process a few times to remove
excess turbine oil remaining in the nozzle.
n
NOTE
A thin coat of oil is enough to lubricate the slide section.
9
Check that the oil was removed.
Blow air through the nozzle again while
placing commercially-available oil blotting
paper over the opposite end of the nozzle,
and check for residual oil in the nozzle.
n
NOTE
Performing step 8 is usually sufficient to remove oil
remaining in the nozzle. However, if oil still remains then
blow air through the nozzle once again.
53394-F9-00
0
Reinstall the nozzle.
Reinstall the nozzle back onto the head after
checking one more time that there is no oil
remaining there.
Lubricating the slide section
Step 6
Nozzle
Precision screwdriver
(with a small amount of turbine oil applied)
Checking the spring action
Step 7
Spring action at nozzle tip
Step 9
Checking for residual oil
Oil blotting paper
Oil may appear after blowing air
(first time) for about 5 seconds from
the nozzle tip.
Repeat the air blow for about 5
seconds each from the nozzle tip
and from the attachment side.
This task is finished when oil no
longer appears.

3-3
3
Periodic maintenance items
1.2 Cleaning Type F nozzles (YG100RA)
1.2.1 Removing FNC nozzle assembly
This section explains how to clean Type F nozzles used with the YG100RA FNC heads.
1
Perform return-to-origin.
Check safety and press the [Origin] button
on the Setup screen.
2
Select "Type 212F nozzle" for the
FNC heads.
On the [Unit]-[Head] tab screen, press the
[Nozzle Change] button and select "Type-
212F" for the FNC heads (Heads 2, 4, 6 and
8).
e
3
Press the emergency stop button.
The machine must be in emergency stop for
safe maintenance work.
4
Slide the stopper block outward.
1. Loosen the bolt securing the stopper
block with the M1.5 hex wrench.
2. Slide the stopper block by pushing on
one end of it.
53341-F9-10
53342-F9-10
5
Pull out the FNC nozzle shaft.
While gripping the nozzle assembly, pull out
the FNC nozzle shaft horizontally along with
the bevel gear.
53343-F9-10
Loosening the bolt securing the stopper block
Step 4-1
Hex wrench (1.5)
Stopper block
Pulling out the FNC nozzle shaft
Step 5
Pull the bevel gear and shaft.
Sliding the stopper block outward
Step 4-2
Slide the stopper block outward.