754_____cmeng0000.pdf - 第6页
753/754 Calibration Manual iv

iii
List of Tables
Table Title Page
1. Symbols .................................................................................................................. 3
2. Equipment Required for Verification ..................................................................... 9
3. DC Volts Measurement Verification Points ........................................................... 11
4. AC Volts Measurement Verification Points ........................................................... 12
5. DC Current Measurement Verification Points ....................................................... 14
6. Resistance Measurement Verification Points ......................................................... 15
7. Frequency Measurement Verification Points ......................................................... 16
8. DC Volts Source Verification Points ..................................................................... 17
9. DC Current Source Verification Points .................................................................. 18
10. Simulate Transmitter Verification Points ............................................................... 20
11. Resistance Source Verification Points ................................................................... 21
12. Frequency Source Verification Points .................................................................... 22
13. Temperature Measure Verification ........................................................................ 25
14. Temperature Source Verification (Type-K Thermocouple, ITS-90) ..................... 26
15. RTD Measure Verification (100W Pt (385), Four-Wire Connection) ................... 27
16. RTD Measure Verification (100W Pt (385), Three-Wire Connection) ................. 28
17. RTD Source Verification (100W Pt (385)) ............................................................ 29
18. Replacement Parts .................................................................................................. 37
19. Accessories ............................................................................................................. 41

753/754
Calibration Manual
iv

v
List of Figures
Figure Title Page
1. DC Volts and AC Volts Measurement Connections .............................................. 11
2. DC Current Measurement Verification Connections ............................................. 13
3. Resistance Measurement Verification Connections ............................................... 15
4. Frequency Measurement Verification Connections ............................................... 16
5. DC Volts Source Verification Connections ........................................................... 17
6. DC Current Source Verification Connections ........................................................ 18
7. Simulate Transmitter Verification Connections ..................................................... 19
8. Resistance Source Verification Connections ......................................................... 20
9. Frequency Source Verification Connections .......................................................... 22
10. Temperature Measure (TC) Verification Connections ........................................... 24
11. Four-Wire RTD Measure Verification Connections .............................................. 27
12. Three-Wire RTD Measure Verification Connections ............................................ 28
13. Loop Power Verification Connections ................................................................... 30
14. Active Device Screen ............................................................................................. 31
15. HART Mode Verification Connections ................................................................. 32
16. Parts ........................................................................................................................ 40