3.3 Error IDs and Remedial Procedures 01 10-003 2 - 73 AFO01ETRP Error ID Item Description 0a0601 F d r .Crg. Axis Motor #3 Emergency stop Servo Error 0a0602 F d r .Crg. Axis Motor #3 Encoder error Servo Error 0a0603 F d…

100%1 / 299
Error ID Item Description
0a05ea Fdr.Crg. Axis Motor #3 Servo pack error
Servo Alarm
0a05eb Fdr.Crg. Axis Motor #3 Servo pack access error
Servo Alarm
0a05ec Fdr.Crg. Axis Motor #3 Servo pack WDC error
Servo Alarm
0a05ed Fdr.Crg. Axis Motor #3 Command not execute
Servo Alarm
0a05f1 Fdr.Crg. Axis Motor #3 Power line open phase
Servo Alarm
0a0591 Fdr.Crg. Axis Motor #3 Overload warning
Servo Alarm
0a0592 Fdr.Crg. Axis Motor #3 Regenerative overload warning
Servo Alarm
0a0594 Fdr.Crg. Axis Motor #3 Data setting warning
Servo Alarm
0a0595 Fdr.Crg. Axis Motor #3 Command warning
Servo Alarm
0a0596 Fdr.Crg. Axis Motor #3 Communication warning
Servo Alarm
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
01 10-003 2-72 AFO01ETRP
3.3 Error IDs and Remedial Procedures
3.3 Error IDs and Remedial Procedures
01 10-003 2-73 AFO01ETRP
Error ID Item Description
0a0601 Fdr.Crg. Axis Motor #3 Emergency stop
Servo Error
0a0602 Fdr.Crg. Axis Motor #3 Encoder error
Servo Error
0a0603 Fdr.Crg. Axis Motor #3 Mechatrolink cut error
Servo Error
0a0604 Fdr.Crg. Axis Motor #3 Location timeout
Servo Error
0a0605 Fdr.Crg. Axis Motor #3 Position error pulse overflow error
Servo Error
0a0606 Fdr.Crg. Axis Motor #3 Software limit (-)
Servo Error
0a0607 Fdr.Crg. Axis Motor #3 Software limit (+)
Servo Error
0a0608 Fdr.Crg. Axis Motor #3 Illegal parameter
Servo Error
0a0609 Fdr.Crg. Axis Motor #3 System error
Servo Error
0a060a Fdr.Crg. Axis Motor #3 Illegal command
Servo Error
0a060b Fdr.Crg. Axis Motor #3 Servo on time out
Servo Error
0a060c Fdr.Crg. Axis Motor #3 Servo off time out
Servo Error
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0a0701 Fdr.Crg. Axis Motor#3 Interlock Movement cannot take place until the index angle
is adjusted.
0a0702 Fdr.Crg. Axis Motor#3 Interlock Pallet went out.
0a0801 Fdr.Crg. Axis Motor#3 Communication error was detected.
Communication
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
Error ID Item Description
0b0101 Fdr.Crg. Axis Motor #4 Origin Encoder origin was not detected.
0b0102 Fdr.Crg. Axis Motor #4 Origin Origin sensor (slide) was not detected.
0b0104 Fdr.Crg. Axis Motor #4 Origin Feedback value is indefinite.
0b0105 Fdr.Crg. Axis Motor #4 Origin The component pick-up (z) axis is not at origin.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0b0201 Fdr.Crg. Axis Motor #4 Timing Task has not been completed unable to continue.
0b0301 Fdr.Crg. Axis Motor #4 Data The driver data was detected outside of the possible range.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0b0401 Fdr.Crg. Axis Motor #4 Limit (+) Limit error has been detected.
0b0402 Fdr.Crg. Axis Motor #4 Limit (-) Limit error has been detected.
0b0403 Fdr.Crg. Axis Motor #4 Limit (+)(-)Limit error has been detected.
(Cause 1) Automatic or manual operation was started without all devices being zeroed after the
machine was powered.
(Remedy 1) Press the [RETURN] button to cancel the error display.
Remove the cause of the error.
Zero all axes and re-start the operation.
01 10-003 2-74 AFO01ETRP
3.3 Error IDs and Remedial Procedures