CX200-4(Maint).pdf - 第220页

Error ID ltem Description 600301 Head Skip Communication Error 600302 Head Skip Head Origin 600303 Head Skip Overtime Head Origin Return 600304 Head Skip Unselected Nozzle Drop 600305 Head Skip Dummy Nozzle 600306 Head S…

100%1 / 299
Error ID ltem Description
600206 Nozzle Skip Nozzle Level
(Cause 1) This error occurs when the L value exceeds the tolerance in comparison with the
master nozzle in the offset data.
(Remedy 1) Check if a big value is set as an L level of the master level in the offset data.
Check if the nozzle is broken or dirt adheres to the end.
600207 Nozzle Skip Nozzle Drop
(Cause 1) When a “NOZ. DOWN ERR (L)” error occurs, the nozzle is bypassed and the nozzle
bypass data indicates that “Bypass” appears as a low nozzle item.
(Remedy 1) Open the “Head/Noz. Bypass” tab sheet in the “OPN. MODE” window (submenu)
and press the [Reset Noz. Bypass] button. The “Bypass” in the “Nozzle Height”
text box disappears, indicating that “Bypass” is canceled.
600208 Nozzle Skip Dummy Nozzle
600209 Nozzle Skip Manual Bypass
(Cause 1) This appears when some nozzles are bypassed manually.
(Remedy 1) When the [Reset Noz. Bypass] button is pressed in the “Head/Noz. Bypass” tab
sheet of the “OPN. MODE” window (submenu), the manual bypass designation of
all nozzles is all canceled.
60020a Nozzle Skip Change Error.(Cam lock action)
60020b Nozzle Skip Nozzle Change Error.(Cam Free action)
60020c Nozzle Skip Cam Origin Error.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
01 10-003 2-130 AFO01ETRP
3.3 Error IDs and Remedial Procedures
Error ID ltem Description
600301 Head Skip Communication Error
600302 Head Skip Head Origin
600303 Head Skip Overtime Head Origin Return
600304 Head Skip Unselected Nozzle Drop
600305 Head Skip Dummy Nozzle
600306 Head Skip Manual Bypass
600307 Head Skip Alarm Error
(Cause 1) Self-Diagnostics Error Message
(Cause 2) The voltage of the stabilization power supply unit (PSU) is abnormal.
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
(Remedy 2) Consult our service personnel for details.
600401 Nozzle Level Nozzle Level (Low) Was More Than Tolerance.
600402 Nozzle Level Nozzle Level (Low) Was Less Than Tolerance.
600403 Nozzle Level Nozzle Level (High) Was More Than Tolerance.
600404 Nozzle Level Nozzle Level (High) Was Less Than Tolerance.
(Cause 1) This error occurs when there is a big difference in nozzle levels in comparison with
the master nozzle during teaching operation.
(Remedy 1) Re-teach the data of the master nozzle.
600501 Master Head Offset Linear Measure System Was At High Position.
600502 Master Head Offset Linear Measure System Was At Low Position.
(Cause 1) The master nozzle or the linear measure detection sensor may not be attached
correctly.
(Remedy 1) Attach the master nozzle correctly.
It is required to adjust the linear measure detection sensor after it is attached
correctly.
01 10-003 2-131 AFO01ETRP
3.3 Error IDs and Remedial Procedures
Error ID ltem Description
600601 Head Origin Offset Total Designate Loop Exceeded Time.
(Cause 1) Each head deviated from its origin position in comparison with the master head.
(Remedy 1) Check if the master head is not loose.
600701 Comp. Thickness Teach Component Thickness Was Less Than Tolerance.
600702 Comp. Thickness Teach Component Thickness Was More Than Tolerance.
(Cause 1) A mistake is found in the component thickness data of the component library data.
(Remedy 1) Set the component thickness data correctly.
600801 Recog. Data Teach Recognition Error Code.
600901 Trash Teach
Trash Teach Error Code.
Note: Refer to “4. Troubleshooting on Recognition System” for details.
01 10-003 2-132 AFO01ETRP
3.3 Error IDs and Remedial Procedures