CX200-4(Maint).pdf - 第274页
Recognition Error ID Item Description 02 ** 3501 ** Error in Lead Detection Some leads cannot be detected because they are hidden by the nozzle. 02 ** 3502 ** Error in Lead Detection No Lead Detected. 02 ** 3503 ** Error…

Recognition Error ID Item Description
02 ** 3301 ** Error in Edge Detection Some edges cannot be detected because they
are hidden by the nozzle.
02 ** 3302 ** Error in Edge Detection No Edge Detected.
02 ** 3303 ** Error in Edge Detection Upper Edge Not Detected.
02 ** 3304 ** Error in Edge Detection Left Edge Not Detected.
02 ** 3305 ** Error in Edge Detection Lower Edge Not Detected.
02 ** 3306 ** Error in Edge Detection Right Edge Not Detected.
(Cause 1)The selected component does not match the nozzle.
(Cause 2) Wrong parameters (edge data) are set for the selected component in the
component library data.
(Cause 3) The tapered part of the vacuum nozzle end or the diffusion plate is stained.
Fig. 4B23
(Remedy 1) Check the selected component and the vacuum nozzle.
Check if the feeder (B) offset data is correct.
(Remedy 2) Check the edge condition of the selected component and the compo-
nent library data.
If wrong parameters are set in the component library data, correct them.
(Remedy 3) Clean the vacuum nozzle end or the diffusion plate.
01 10-003 2-184 AFO01ETRP
Component
Vacuum Nozzle
Dirty Spots
4.3 Recognition Error IDs and Remedial Procedures

Recognition Error ID Item Description
02 ** 3501 ** Error in Lead Detection Some leads cannot be detected because they
are hidden by the nozzle.
02 ** 3502 ** Error in Lead Detection No Lead Detected.
02 ** 3503 ** Error in Lead Detection Corner of Leads Not Detected.
02 ** 3504 ** Error in Lead Detection Ends of Leads Not Detected.
02 ** 3505 ** Error in Lead Detection Ends of Arrayed Leads Not Detected.
02 ** 3506 ** Error in Lead Detection Lead Edges of Corner Not Detected.
02 ** 3507 ** Error in Lead Detection Leads of Corner Not Detected.
02 ** 3508 ** Error in Lead Detection The number of leads at the detected corner is
smaller than the set value.
02 ** 3509 ** Error in Lead Detection Incorrect Lead-to-Lead Distance at Detected
Corner.
02 ** 3510 ** Error in Lead Detection Incorrect Lead-to-Lead Angle at Detected Cor-
ner.
(Cause 1) The results of the lead detection differ from the parameters specified in
the component library data for the selected components.
(Remedy 1) Check the leads of the selected component and the component library
data.
If wrong parameters are set in the component library data, correct them.
01 10-003 2-185 AFO01ETRP
4.3 Recognition Error IDs and Remedial Procedures

Recognition Error ID Item Description
02 ** 3512 ** Error in Lead Detection The detected number of leads is smaller than
the set value.
02 ** 3513 ** Error in Lead Detection The detected number of leads is larger than the
set value.
(Cause 1) The results of the lead detection differ from the parameters specified in
the component library data for the selected components.
(Remedy 1) Check the leads of the selected component and the component library
data.
If wrong parameters are set in the component library data, correct them.
02 ** 8001 ** Data Error Data Error in Process
02 ** 8002 ** Data Error Error in Lighting Data
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Contact our service personnel for details.
02 ** 9001 ** Other Errors Internal Processing Error
02 ** 9002 ** Other Errors Impossible to set the detection window.
02 ** 9003 ** Other Errors Impossible to set the window for arrayed lead
end detection.
02 ** 9004 ** Other Errors Impossible to set the window for lead detection
at the corner.
02 ** 9005 ** Other Errors Impossible to set the window for lead detection.
02 ** 9006 ** Other Errors Angle Calculation Impossible.
02 ** 9007 ** Other Errors Internal Processing Error.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Contact our service personnel for details.
01 10-003 2-186 AFO01ETRP
4.3 Recognition Error IDs and Remedial Procedures