CX200-4(Maint).pdf - 第200页

3.3 Error IDs and Remedial Procedures 01 10-003 2 - 111 AFO01ETRP Error ID Item Description 430701 Linear Measure Linear measure alarm signal was detected. 430702 Linear Measure Communication error in linear measure syst…

100%1 / 299
Notes: (a) When the power is re-supplied without following the correct procedure
to cancel the error, the feeder installation error will be detected again
and the message will be issued because the contents of the feeder
installation error are backed up.
(b) No zeroing operation can be performed when a feeder installation error
is not canceled completely.
(1) Confirm that there is no error in the feeder installation sections.
(2) Select the object feeder and the direction of the movement. After that, press
the [ENABLE] button to move the feeder carriage to the position where the
error-caused feeder can be re-installed correctly.
Note: While the [ENABLE] button is held down, the feeder carriages keep on
moving.
(3) Check the cause of the error and re-install the feeder correctly.
(4) Press the [RETURN] button.
Ref.: The original window resumes.
(5) Zero all axes and re-start the operation.
01 10-003 2-110 AFO01ETRP
3.3 Error IDs and Remedial Procedures
Rear View (Upper Section)
Fig. 4B18-1 Location of Feeder Installation Error Sensors
3.3 Error IDs and Remedial Procedures
01 10-003 2-111 AFO01ETRP
Error ID Item Description
430701 Linear Measure Linear measure alarm signal was detected.
430702 Linear Measure Communication error in linear measure system.
430703 Linear Measure Upper limit of linear measure data was out of range.
430704 Linear Measure Lower limit of linear measure data was out of range.
430705 Linear Measure Linear measure dirty signal was detected.
430706 Linear Measure Linear measure SYNC signal has been lost.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
430801 Cam-Positioner Cam-positioner alarm signal was detected.
(Cause 1) The cam positioner is abnormal.
(Remedy 1) Press the [RETURN] button to cancel the error display and contact our service
personnel for the remedy.
430901 Auto Recovery Cannot recover sequence.
430a01 Oil Cooler Oil cooler alarm signal was detected.
430a02 Oil Cooler
430b01 Cooling FAN Cooling FAN alarm signal was detected.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
Error ID ltem Description
440101 Cam Phase Gap of cam phase has been detected.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
440201 The Comp. Placement Lever The structure of comp. placement lever was not activated.
440202 The Comp. Placement Lever The comp. placement lever moves despite being held by stop-
per.
440203 The Comp. Placement Lever The comp. placement lever does not move even though stop-
per was open.
(Cause 1) The sensor is defective or is not adjusted to the correct position.
The sensor does not turn ON or OFF due to adhered dirt.
(Remedy 1) Wipe off dirt on the sensor and zero all axes again.
440301 The Comp. Pick-Up Lever The structure of comp. pick-up lever was not activated.
440302 The Comp. Pick-Up Lever The comp. pick-up lever moves despite being held by stopper.
440303 The Comp. Pick-Up Lever The comp. pick-up lever does not move even though stopper
was open.
(Cause 1) The sensor is defective or is not adjusted to the correct position.
The sensor does not turn ON or OFF due to adhered dirt.
(Remedy 1) Wipe off dirt on the sensor and zero all axes again.
01 10-003 2-112 AFO01ETRP
3.3 Error IDs and Remedial Procedures