CX200-4(Maint).pdf - 第254页

Recognition Error ID Item Description 01 38 2 00000 Unavailable fiducial mark code was set. ---- 01 38 2 00001 “Mark Size D2” is too big, compared with “D1”. ---- 01 38 2 00002 “Mark Size D3” is too big, compared with “D…

100%1 / 299
Recognition Error ID Item Description
01 31 3 00001 Error in “Camera POSITION X or POSITION Y” ----
Data.
01 31 3 00003 Error in “Camera ANGLE” Data. ----
01 31 3 00007 Error in “Camera 1 – 2 X or Y” Data. ----
01 32 3 00002 Error in “Camera GAIN or LEVEL” Data. ----
01 33 3 00001 Error in “Nozzle Offset High Mag. X or Y” Data. ----
01 33 3 00002 Error in “Nozzle Offset Low Mag. X or Y” Data. ----
01 33 3 00004 Error in “Nozzle O.D.Size” Data. ----
01 33 3 00005 Error in “Nozzle I.D.Size” Data. ----
01 33 3 00008 Error in “Nozzle V-Groove Size” Data. ----
01 34 3 00001 Error in “Indidual Nozzle Gain or Level” Data. ----
01 35 3 00001 Error in “Nozzle High or Low level offset” Data. ----
01 36 3 00001 Error in “Nozzle Position Offset” Data. ----
01 37 3 00001 Error in “Head Center X or Y Offset” Data. ----
(Cause) Wrong parameters are set.
(Remedy) Set correct parameters.
4.3 Recognition Error IDs and Remedial Procedures
01 10-003 2-164 AFO01ETRP
Recognition Error ID Item Description
01 38 2 00000 Unavailable fiducial mark code was set. ----
01 38 2 00001 “Mark Size D2” is too big, compared with “D1”. ----
01 38 2 00002 “Mark Size D3” is too big, compared with “D1”. ----
01 38 2 00003 “Mark Size D2” is too big, comapred with“D3”. ----
01 38 2 00004 “Window Size” is smaller than “Mark Size”. ----
01 38 2 00005 “Mark Size D2” is not set. ----
01 38 2 00006 “Mark Size D3” is not set. ----
01 38 3 00001 Error in “P.C.B Recognition Mark Data Mark Size ----
D1 or D2 or D3” Data.
01 38 3 00003 Error in “P.C.B Recognition Mark Data Window ----
Size” Data.
(Cause) Wrong parameters are set for the P.E.C. recognition function.
(Remedy) Refer to “Section 2 Pattern Program” in “Vol. 3” for details and set correct
parameters.
4.3 Recognition Error IDs and Remedial Procedures
01 10-003 2-165 AFO01ETRP
Recognition Error ID Item Description
01 39 2 11001 An improper parameter is specified as ----
“Component shape”.
01 39 2 11002 “Mold Size Tolerance X” is larger than “Mold
----
Size X”.
01 39 2 11003 “Mold Size Tolerance Y” is larger than “Mold
----
Size Y”.
01 39 2 11004 “Outward Length Tolerances” are larger than
----
“Outward Length”.
01 39 2 12001 The total of “Corner 1 Dim X” and “Corner 4 Dim
----
X” is larger than “Mold Size X”.
01 39 2 12002 The total of “Corner 1 Dim Y” and “Corner 2 Dim
----
Y” is larger than “Mold Size Y”.
01 39 2 12003 The total of “Corner 2 Dim X” and “Corner 3 Dim
----
X” is larger than “Mold Size X”.
01 39 2 12004 The total of “Corner 3 Dim Y” and “Corner 4 Dim
----
Y” is larger than “Mold Size Y”.
01 39 2 12005 “Electrode Size” is larger than half of “Mold
----
Size X”.
01 39 2 13001 “# of Types” (lead data) is improper.
----
01 39 2 13002 “# of Groups” (lead data) is improper. ----
01 39 2 13003 The total of “# of Leads” (lead data) is too small. ----
01 39 2 13004 “No Detection” is set in all “Insp Condtn” text ----
boxes.
01 39 2 13005 “Lead Type No.” in “Lead Group 1” is improper.
----
01 39 2 13006 “Lead Type No.” in “Lead Group 2” is improper. ----
01 39 2 13007 “Lead Type No.” in “Lead Group 3” is improper. ----
01 39 2 13008 “Lead Type No.” in “Lead Group 4” is improper ----
01 39 2 13009 “Lead Type No.” in “Lead Group 5” is improper. ----
01 39 2 13010 “Lead Type No.” in “Lead Group 6” is improper. ----
(Cause) Wrong parameters are set.
(Remedy) Set correct parameters.
4.3 Recognition Error IDs and Remedial Procedures
01 10-003 2-166 AFO01ETRP