CX200-4(Maint).pdf - 第260页

Recognition Error ID Item Description 01 39 3 10001 “Component Library Polarity Component shape” ---- Not Supported! (Cause) The data is not supported. (Remedy) Set the supported data. 01 39 3 1 1001 Error in “Component …

100%1 / 299
Recognition Error ID Item Description
01 39 2 14021 “Polarity Inspection Position” Out of “Mold Size” ----
01 39 2 14022 “Elctd # of Rows or # of Cols” in "Elctd Group 1" ----
is Not Sufficient
01 39 2 14023 “Elctd # of Rows or # of Cols” in "Elctd Group 2" ----
is Not Sufficient
01 39 2 14024 “Elctd # of Rows or # of Cols” in "Elctd Group 3" ----
is Not Sufficient
01 39 2 14025 “Elctd # of Rows or # of Cols” in "Elctd Group 4" ----
is Not Sufficient
01 39 2 14026 “Elctd # of Rows or # of Cols” in "Elctd Group 5" ----
is Not Sufficient
01 39 2 14027 “Elctd # of Rows or # of Cols” in "Elctd Group 6" ----
is Not Sufficient
01 39 2 14028 Electrode Position Superposed in Different ----
Electrode Group!
01 39 2 21001 Failed in Automatic Selection of Algorithm for ----
Lealess Components.
01 39 2 21002 Failed in Automatic Selection of Algorithm for ----
Leaded Components.
01 39 2 21003 Failed in Automatic Selection of Algorithm for ----
Area Array.
01 39 2 21004 Failed in Automatic Selection of Algorithm for ----
Cylindrical Components.
01 39 2 21005 Failed in Automatic Selection of Algorithm for ----
Square Components.
01 39 2 21006 Failed in Automatic Selection of Algorithm for ----
Deformed Components.
01 39 2 21007 Failed in Automatic Selection of Algorithm for ----
ICs.
01 39 2 21008 Failed in Automatic Selection of Algorithm for ----
Connectors.
01 39 2 21009 Failed in Automatic Selection of Algorithm for ----
Leaded Components.
01 39 2 21010 Failed in Automatic Selection of Algorithm for ----
BGA Components.
01 39 3 00005 Error in “Component Library Pickup Pos ----
Correction X or Y” Data.
(Cause) Wrong parameters are set.
(Remedy) Set correct parameters.
01 10-003 2-170 AFO01ETRP
4.3 Recognition Error IDs and Remedial Procedures
Recognition Error ID Item Description
01 39 3 10001 “Component Library Polarity Component shape” ----
Not Supported!
(Cause) The data is not supported.
(Remedy) Set the supported data.
01 39 3 11001 Error in “Component Library Mold Size X or Y” ----
Data
01 39 3 11002 Error in “Component Library Mold Size T or t or ----
Ut” Data
01 39 3 11003 Error in “Component Library Outward Length” ----
Data
(Cause) Wrong parameters are set.
(Remedy) Set correct parameters.
01 39 3 12001 “Component Library Component type” Not ----
Supported!
(Cause) The data is not supported.
(Remedy) Set the supported data.
01 39 3 12002 Error in “Component Library Elctd Size” Data ----
01 39 3 12112 Error in “Component Library Corner Dim X or Y” ----
Data
01 39 3 12212 Error in “Component Library Edge Detection ----
Posn” Data
01 39 3 12301 Error in “Component Library Number of Linear ----
Edges” Data
01 39 3 12311 Error in “Component Library Linear Start ----
Position” Data
01 39 3 12312 Error in “Component Library Linear Direction” ----
Data
01 39 3 12313 Error in “Component Library Linear Width ----
(Length)” Data
(Cause) Wrong parameters are set.
(Remedy) Set correct parameters.
01 10-003 2-171 AFO01ETRP
4.3 Recognition Error IDs and Remedial Procedures
Recognition Error ID Item Description
01 39 3 13002 “Component Library Lead Type” Not Supported! ----
01 39 3 13111 “Component Library Polarity Lead Shape” Not ----
Supported!
(Cause) The data is not supported.
(Remedy) Set the supported data.
01 39 3 13112 Error in “Component Library Lead Width” Data ----
01 39 3 13113 Error in “Component Library Lead Length” Data ----
01 39 3 13114 Error in “Component Library Lead Full Length” ----
Data
01 39 3 13212 Error in “Component Library Lead Center ----
Posn(Latl)Det” Data
01 39 3 13213 Error in “Component Library Lead Top ----
Posn(Long)Det” Data
01 39 3 13214 Error in “Component Library Lead Direction” ----
Data
01 39 3 13215 Error in “Component Library Lead # of Leads” ----
Data
01 39 3 13216 Error in “Component Library Lead Pitch” Data ----
01 39 3 13217 Error in “Component Library Lead Missing Lead ----
Start” Data
01 39 3 13218 Error in “Component Library Lead # of Missing ----
Leads” Data
(Cause) Wrong parameters are set.
(Remedy) Set correct parameters.
01 10-003 2-172 AFO01ETRP
4.3 Recognition Error IDs and Remedial Procedures