CX200-4(Maint).pdf - 第60页

(1-2) Mov e the head (having the nozzle to be detached) to the place- ment station with the [Manual Alignment] button in the “Mnl Opn Menu” tab sheet. (Operation Sequence: “UNIT ADJ.” Window (Submenu) Æ “Nozzle Adj.” T a…

100%1 / 299
1.4.4 Detachment and Attachment of Vacuum Nozzle
The vacuum nozzles must be detached or attached
with the operation power being turned “ON”
It is dangerous. Be sure to detach or attach a vacuum
nozzle alone (without any other attended personnel).
Before detaching or attaching a vacuum nozzle, be
sure to spread a rag under the working area.
Otherwise, a fallen vacuum nozzle will easily be lost if
any.
To facilitate the detachment or the attachment of the vacuum nozzle,
move the X/Y table in the X (plus) direction to leave a space under the
placement station.
Use the [Table X] button in the “Others” tab sheet to move the
X/Y table. (Operation Sequence: “MNL OPN.” Window
(Submenu) Æ “Manual Axis Opn” Tab Æ “Others” Tab Æ
[Table X] Button).
(1) Detachment of Vacuum Nozzle
(1-1) Set the [OPERATION] switch to the “SETUP” side.
Confirm that the “LOCK” lamp on the front operation panel is
“ON”
0110-003 1-48
AFO01ETRP
1.4 Maintenance Method
CAUTION
CAUTION
Note
(1-2) Move the head (having the nozzle to be detached) to the place-
ment station with the [Manual Alignment] button in the “Mnl Opn
Menu” tab sheet. (Operation Sequence: “UNIT ADJ.” Window
(Submenu) Æ “Nozzle Adj.” Tab Æ “Mnl Opn Menu” Tab Æ
[Manual Alignment] Button)
Fig. 4A64 “Mnl Opn Menu” Tab Sheet
(1-3) Select one of the buttons (Head Nos.) in “*2”, the [Auto] button
(*3), the [LOW] button (*4), and the [Cam Lock Positioning]
(*5).
Press the [ENABLE] button on the operation panel in two sec-
onds after the [ON] button (entitled “MOVE”).
The “LOW” nozzle on the specified head turns toward the front
side of the machine.
If the head does not turn, use the [Zeroing Head] button (*6) to
zero the specified head and perform the above operation
again.







1.4 Maintenance Method
0110-003 1-49 AFO01ETRP
Note
(1-4) Press the [Cam Lock] switch on the head.
Fig. 4A64-1
(1-5) Select one (Nozzle # of the nozzle to be detached) of the but-
tons in “*7” and press the [ON] button (entitled “MOVE”). In two
seconds, press the [ENABLE] button on the operation panel.
The selected vacuum nozzle will face toward the front side of
the machine. Press the [Cam Unlock] switch.
1.4 Maintenance Method
0110-003 1-50 AFO01ETRP