Error ID Item Description 400101 Abnormal Front Safety Door The machine’s front safety door (lower) is open. 400102 Abnormal Front Safety Door The rotary hand wheel has been inserted. (Cause 1) The front safety door was …

100%1 / 299
Error ID Item Description
140201 P.C.B. LOCATE LEVER TIMING TASK HAS NOT BEEN COMPLETED UNABLE TO
CONTINUE.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
140301 P.C.B. LOCATE LEVER DATA THE DRIVER DATA WAS DETECTED OUTSIDE OF THE
POSSIBLE RANGE.
(Cause 1) The target value has exceeded the movable range of the device.
(Remedy 1) As the P.C.B. thickness has exceeded the specified value, set the data correctly.
140401 P.C.B. LOCATE LEVER LIMIT LIMIT ERROR HAS BEEN DETECTED. ; BPH94 E/NR
140402 P.C.B. LOCATE LEVER LIMIT LIMIT ERROR HAS BEEN DETECTED. ; BPH95 E/NR
(Cause 1) Dirt adheres to the sensor and the optical beam is shielded.
(Cause 2) The sensor may be defective.
(Remedy 1) Wipe off dirt on the sensor and re-zero the support pin up/down mechanism.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
(Remedy 2) Contact our service personnel for details.
140601 P.C.B. LOCATE LEVER THE CONTROLLER CAN NOT RUN.
COMMUNICATION
140602 P.C.B. LOCATE LEVER CONTROLLER INTERIOR IS OUT OF ORDER.
COMMUNICATION
140603 P.C.B. LOCATE LEVER CONTROLLER IN COMMUNICATION ERROR CONDITION.
COMMUNICATION
140604 P.C.B. LOCATE LEVER CONTROLLER INCOMPLETE RESULTING IN AN OVERTIME
ALARM.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
01 10-003 2-98 AFO01ETRP
3.3 Error IDs and Remedial Procedures
Error ID Item Description
400101 Abnormal Front Safety Door The machine’s front safety door (lower) is open.
400102 Abnormal Front Safety Door The rotary hand wheel has been inserted.
(Cause 1) The front safety door was opened with the machine in the operation mode.
(Cause 2) The cam hand-rotating wheel is inserted into the motor shaft of the rotary turret.
(Remedy 1) Press the [RETURN] button to cancel the error display and press the [POWER]
button again. After the machine is powered up, perform the zeroing operation on
all axes.
(Remedy 2) Detach the cam hand-rotating wheel.
400201 Fdr.Crg. Axis Safety Guard The fdr.crg. #1 home location safety guard is open.
400202 Fdr.Crg. Axis Safety Guard The fdr.crg. #2A home location safety guard is open.
400203 Fdr.Crg. Axis Safety Guard The fdr.crg. #3B home location safety guard is open.
400204 Fdr.Crg. Axis Safety Guard The fdr.crg. #2B home location safety guard is open.
400205 Fdr.Crg. Axis Safety Guard The fdr.crg. #3A home location safety guard is open.
400206 Fdr.Crg. Axis Safety Guard The fdr.crg. #4 home location safety guard is open.
400207 Fdr.Crg. Axis Safety Guard The fdr.crg. Axis safety guard (a) is open.
400208 Fdr.Crg. Axis Safety Guard The fdr.crg. Axis safety guard (b) is open.
400211 Fdr.Crg. Axis Safety Guard The fdr.crg. #1 home location safety guard is open.
400216 Fdr.Crg. Axis Safety Guard The fdr.crg. #2 home location safety guard is open.
400221 Fdr.Crg. Axis Safety Guard The fdr.crg. #12 home location safety guard is open.
400226 Fdr.Crg. Axis Safety Guard The fdr.crg. #34 home location safety guard is open.
400231 Fdr.Crg. Axis Safety Guard The fdr.crg. #1A home location safety guard is open.
400236 Fdr.Crg. Axis Safety Guard The fdr.crg. #1B home location safety guard is open.
(Cause 1) The safety cover was opened while the feeder carriage was moving.
(Cause 2) The [START] button was pressed with the safety cover being open.
(Remedy 1) Close the safety cover.
(Remedy 2) Press the [RETURN] button to cancel the error display and then zero all axes.
3.3 Error IDs and Remedial Procedures
01 10-003 2-99 AFO01ETRP
Error ID Item Description
400301 Load Power Circuit The [emergency stop] button was pressed.
Refer to “2.3 [EMERGENCY STOP] Button Pressed” for “(Cause 1)” and “(Remedy 1)”.
400302 Load Power Circuit The air pressure is too low.
(Cause 1) The main air pressure has dropped below the specified one.
.
Fig. 4B16
(Remedy 1) Adjust the pressure to the correct one.
Turn Knob (1) to adjust the main air pressure to the specified one (0.45 MPa (4.6
kgf/cm
2
)).
400303 Load Power Circuit Circuit porotector is active.
(Cause 1) The circuit breaker in the machine was activated.
(Remedy 1) Consult our service personnel for details.
400304 Load Power Circuit The machine’s front safety door is open.
(Cause 1) The front safety door was opened.
(Remedy 1) Close the front safety door after pressing the [RETURN] button and zero all axes.
Then, re-start the operation.
01 10-003 2-100 AFO01ETRP
3.3 Error IDs and Remedial Procedures