CX200-4(Maint).pdf - 第94页

Check Code Display Section A Display Section B 030120 Operator’s Error Check the feeder . (the feeder checker) 030121 Operator’s Error Remove the P .C.B. at the inlet of input buffer cnvr . 030122 Operator’s Error Check …

100%1 / 299
1.2.2 List of Check Messages
Table 4B1
Check Code Display Section A Display Section B
010101 Emergency Stop Turn on the [POWER ON] button.
010201 Air Pressure Drop Increase air pressure and press the [POWER ON] button to power
up the machine.
010301 Feeder Axis Central Close the feeder safety guard and press the [POWER ON] button
Safety Guard to power up the machine.
010401 Front Side Safety Door Close the safety door and press the [POWER ON] button to power
up the machine.
010501 Circuit Protector Circuit protector is active in the machine.
010601 Control Power Source
030101 Operator’s Error Set operation mode to “placement”.
030102 Operator’s Error Please select the available menu.
030103 Operator’s Error Input registered test ID.
030104 Operator’s Error Select correct combination of camera and lighting mode.
030105 Operator’s Error Selected available carriage.
030106 Operator’s Error Cancel the component shortage designated position stop function.
030107 Operator’s Error Recovery mode is not available while grouped component function
is implemented.
030108 Operator’s Error Set “ENABLE” for destination alternate feeder.
030109 Operator’s Error Machine is in “PAUSE” mode.
03010a Operator’s Error Stop the input cnvr. (+) movement in manual mode.
03010b Operator’s Error Stop the input cnvr. (-) movement in manual mode.
03010c Operator’s Error Input correct data for manual axis operation.
03010d Operator’s Error Please input correct nozzle type data.
03010e Operator’s Error Input non-defective P.C.B. (O-NO.)
03010f Operator’s Error Wait until data communication with external device is completed.
030110 Operator’s Error P.C.B.’s were at inlet and outlet of input buffer cnvr.
030111 Operator’s Error P.C.B.’s were at inlet and outlet of input cnvr.
030112 Operator’s Error P.C.B. on Inp. Cnvr. was not able to move to its transfer action.
030113 Operator’s Error P.C.B. stop movement in manual mode.
030114 Operator’s Error Please input the test ID.
030115 Operator’s Error Please cancel “set up” mode as closing a safe cover.
030116 Operator’s Error P.C.B.’s were at inlet and outlet of output cnvr.
030117 Operator’s Error Remove the P.C.B. at the inlet of output cnvr.
030118 Operator’s Error Remove P.C.B. on the L conveyor.
030119 Operator’s Error Remove P.C.B. on the R conveyor.
03011a Operator’s Error Remove P.C.B. on the X/Y table.
03011b Operator’s Error Cannot start in CVS start protection mode.
03011c Operator’s Error Remove P.C.B. on the conveyor.
03011d Operator’s Error Cancel the start protect mode.
03011e Operator’s Error Out of range P.C.B. is exist on the conveyor.
(lot management production)
03011f Operator’s Error Not released p-out mode.
01 10-003 2-4 AFO01ETRP
1.2 “CHECK” Windows
Check Code Display Section A Display Section B
030120 Operator’s Error Check the feeder. (the feeder checker)
030121 Operator’s Error Remove the P.C.B. at the inlet of input buffer cnvr.
030122 Operator’s Error Check the program name of bar code.
(the P.C.B. is on the input cnvr.)
030123 Operator’s Error It isn’t practicable with “set up” mode.
030124 Operator’s Error It isn’t practicable with “P.C.B. clamp valve” menu select.
030125 Operator’s Error Please read of barcode label on the P.C.B.
030126 Operator’s Error The fdr. was not recorded SIF data exists.
Please record by mnl. operation.
030128 Operator’s Error The fdr. was not recorded SIF data exists.
Please record by mnl. operation.
03012a Operator’s Error Remove the P.C.B. at the input cnvr.
03012b Operator’s Error Cannot start by external start protection.
03012c Operator’s Error Please change enable mode into disable mode.
(serial out mode)
03012d Operator’s Error Remove the P.C.B. at the input cnvr.
(the P.C.B. not enable B.B.R. info.)
03012e Operator’s Error Cannot start by the unit P.C.B. B.B.R. mode (conveyor).
03012f Operator’s Error Remove the P.C.B. at middle position of input buffer cnvr.
030130 Operator’s Error Cannot start by external start protection. (F1)
030131 Operator’s Error Cannot start by external start protection. (F2)
030132 Operator’s Error Cannot start by Machine is already in “running” mode.
030133 Operator’s Error Enable SW is busy status.
030134 Operator’s Error Cannot start by Machine is already in “running” unit.
030135 Operator’s Error Cannot start by Machine is not in “STOP” mode.
030136 Operator’s Error Cannot start by Machine is not in “STOP” or ”PAUSE” mode.
030137 Operator’s Error Remove the P.C.B. at inside the L1 cnvr.
030138 Operator’s Error Remove the P.C.B. at outside the L1 cnvr.
030139 Operator’s Error Remove the P.C.B. at inside the L2 cnvr.
03013a Operator’s Error Remove the P.C.B. at outside the L2 cnvr.
03013b Operator’s Error Remove the P.C.B. at inside the R1 cnvr.
03013c Operator’s Error Remove the P.C.B. at outside the R1 cnvr.
03013d Operator’s Error Remove the P.C.B. at inside the R2 cnvr.
03013e Operator’s Error Remove the P.C.B. at outside the R2 cnvr.
03013f Operator’s Error
030201 Out Of Specified Rotate the rotary turret to designated angle.
Rotary Turret Angle
030301 Head Bypass Cancel bypass operation of selected head or do not use the head.
030302 Head Bypass The specified head is bypassed.
01 10-003 2-5 AFO01ETRP
1.2 “CHECK” Windows
Check Code Display Section A Display Section B
030303 Head Bypass The specified nozzle is bypassed.
030401 Operation Please input barcode data by manual input screen.
Requirement
030402 Operation Please check the operation in “pass” mode.
Requirement
030403 Operation X/Y chute P.C.B. detection is one side mode.
Requirement
030404 Operation Please exit P.E.C. manual adjustment mode.
Requirement (Click right and left button)
030405 Operation Please wait for a while.
Requirement (Now Machine is initializing.)
050101 No Current Select the current program.
050201 Setup Check Set up X/Y chute width.
050202 Setup Check Set up L conveyor width.
050203 Setup Check Set up R conveyor width.
050204 Setup Check Set up conveyor width.
050205 Setup Check Move the X/Y chute up.
050206 Setup Check Set up PCB support pins up/down.
050207 Setup Check Set up PCB locate lever.
050301 Recognition Data Please check recognition nozzle data and carry out data trans again.
Missing
050302 Recognition Data Please check comp recog lighting data and carry out data trans
Missing again.
050303 Recognition Data Please check recog camera mag data and carry out data trans
Missing again.
050304 Recognition Data Please check recog camera offset data and carry out data trans
Missing again.
050305 Recognition Data Please check recog camera gain level data and carry out data trans
Missing again.
050306 Recognition Data Please check recog nozzle gain level data and carry out data trans
Missing again.
050307 Recognition Data Please check comp recog data and carry out data trans again.
Missing
050308 Recognition Data Please check recog execution mode data and carry out data trans
Missing again.
070101 Front Safety Door Close the safety door and zero all device with the [ZERO] button.
070201 Rotary Wheel Pull on the rotary wheel handle.
070301 Front Area Sensor Remove foreign substance.
070401 Unavailable Data Input available feeder No. in current program.
070402 Unavailable Data Input available placement step in current program.
090101 Disengaged PCB Set P.C.B. on the X/Y table.
090201 Chute Lower Limit Move the X/Y chute down.
090301 Feeder Carriage Separate both feeder carriages and zero all devices with the [ZERO]
Collision button.
01 10-003 2-6 AFO01ETRP
1.2 “CHECK” Windows