Error ID ltem Description 460101 PEC Inspect P .E.C. Mark #1 (Global) 460201 PEC Inspect P .E.C. Mark #2 (Global) 460301 PEC Inspect P .E.C. Mark #3 (Global) 460401 PEC Inspect P .E.C. Mark #1 (Image) 460501 PEC Inspect …

100%1 / 299
Error ID ltem Description
440801 Cutter THE CUTTER FORWARD CONFIRMATION WAS NOT ACTI-
VATED. ; BPH32
440802 Cutter THE CUTTER RETURN CONFIRMATION WAS NOT ACTI-
VATED. ; BPH33
(Cause 1) An optical beam of the sensor was not shielded at all.
This error occurs when the cutter blades do not close completely.
Example: The cutter blades were damaged because they were activated to cut com-
ponents.
(Remedy 1) Press the [RETURN] button to cancel the error display and check the cutter
blades.
If necessary, replace the cutter blades with new ones.
Check the ON/OFF operation of the cutter forward movement check photosensor
(BPH32) and the cutter backward movement check photosensor (BPH33) in
the cutter section through the manual subsystem operation in the “MNL OPN.”
window.
450101 PEC INSPECT
450102 PEC INSPECT Time-Out Error
450103 PEC INSPECT GUI starting failure.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
01 10-003 2-116 AFO01ETRP
3.3 Error IDs and Remedial Procedures
Error ID ltem Description
460101 PEC Inspect P.E.C. Mark #1 (Global)
460201 PEC Inspect P.E.C. Mark #2 (Global)
460301 PEC Inspect P.E.C. Mark #3 (Global)
460401 PEC Inspect P.E.C. Mark #1 (Image)
460501 PEC Inspect P.E.C. Mark #2 (Image)
460601 PEC Inspect P.E.C. Mark #3 (Image)
460701 PEC Inspect P.E.C. Mark #1 (Local)
460801 PEC Inspect P.E.C. Mark #2 (Local)
460901 PEC Inspect P.E.C. Mark #3 (Local)
460a01 PEC Inspect P.E.C. Recognition Test
460b01 PEC Inspect P.E.C. Recog. Light Teach
460c01 PEC Inspect Error Response of P.E.C. Recog. Command
Refer to “4.3.3 P.E.C. Recognition Errors” for “(Cause 1)” and “(Remedy 1)”.
01 10-003 2-117 AFO01ETRP
3.3 Error IDs and Remedial Procedures
Error ID ltem Description
470101 Comp. Missing(Sensor)
(Cause 1) The machine stopped running because the linear measure detection sensor detected
the “Component Missing (Sensor)” error continuously.
Ref.: When “2” is set in the “1” text box of “Error process” in the component library
data, it means that a pick-up error occurred continuously twice on the same
feeder No.
Note: This detection cannot be made when “less than 0.15 mm” is set in the “t” text
box of “Component thickness” in the component library data or the carrier
data.
(Remedy 1) Follow the steps below to reset the machine to the normal condition.
(1) Check “Step” and “Feeder No.” where an error has occurred.
(2) Press the [RETURN] and [ALL] button (entitled “ZERO”). After that, check the
following items related to the pertinent feeder No.
Check if some components are left in the tape feeder.
Check if the cover tape is peeled off normally.
Check if the tape feeder is installed correctly on the feeder carriage.
Check if the tape feeder is loaded with correct components.
Check if some components are left in the carrier tape.
If left, be sure to remove them to protect the cutter blades from being
damaged.
Check if the vacuum nozzle is not clogged or proper vacuum pressure is
applied.
(3) After taking the required countermeasures, re-start the production.
470201 Comp. Vertical(Sensor)
(Cause 1) The machine stopped running because the linear measure detection sensor de-
tected the “Vertical Component (Sensor)” error continuously.
Ref.: When “9” is set in the “2” text box of “Error process” in the component library
data, it means that a pick-up error occurred continuously 9 times on the same
feeder No.
(Remedy 1) Follow the steps below to reset the machine to the normal condition.
(1) Check “Step” and “Feeder No.” where an error has occurred.
(2) Press the [RETURN] and [ALL] button (entitled “ZERO”). After that, check the
following items related to the pertinent feeder No.
Check if the tape feeder is loaded with correct components.
Check the selected components and the parameter set in the “Vertical
cmpnt data[mm]” text box in the component library data. If a wrong param-
eter is set, correct it.
Note: Check the parameter set as vertical component data in the “CMPNT
CARRIAGE DATA EDIT” window.
(3) After taking the required countermeasures, re-start the production.
01 10-003 2-118 AFO01ETRP
3.3 Error IDs and Remedial Procedures