CX200-4(Maint).pdf - 第195页

Error ID Item Description 430203 NOZZLE POSITION THE SELECTED NOZZLE LEVEL W AS NOT A T HIGH PO- SITION.; BPH16 430204 NOZZLE POSITION THE SELECTED NOZZLE LEVEL W AS NOT A T LOW POSION.; BPH16 (Cause 1) The optical beam …

100%1 / 299
Error ID Item Description
420601 Output Cnvr. P.C.B. Detection Out. machine work req. sig. turned off before P.C.B. trns.act
completed.
420602 Output Cnvr. P.C.B. Detection P.C.B. on output cnvr. was not able to move to its outlet.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
430101 Nozzle Change Nozzle change action error.(DD-head camfree position)
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
430201 NOZZLE POSITION The nozzle dropped.; BPX29
(Cause 1) The optical beam was not set in the “E/R” or the “E/NR” condition due to dirt on the
sensor. (E/R: Light Emitted and Received, E/NR: Light Emitted and Not Received)
The sensor may be defective.
(Cause 2) The nozzle is not attached correctly.
(Remedy 1) Press the [RETURN] button to cancel the error display and check that no dirt
adheres to the sensor.
(Remedy 2) Attach the nozzle correctly.
430202 NOZZLE POSITION THE SELECTED NOZZLE WAS ERRONEOUSLY POSI-
TIONED.; BPH15
(Cause 1) The selected nozzle moved down, passing over the low level at Station #10.
Self-Diagnostics Error Message.
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
01 10-003 2-105 AFO01ETRP
3.3 Error IDs and Remedial Procedures
Error ID Item Description
430203 NOZZLE POSITION THE SELECTED NOZZLE LEVEL WAS NOT AT HIGH PO-
SITION.; BPH16
430204 NOZZLE POSITION THE SELECTED NOZZLE LEVEL WAS NOT AT LOW
POSION.; BPH16
(Cause 1) The optical beam was not set in the “E/R” or the “E/NR” condition due to dirt on the
sensor. (E/R: Light Emitted and Received, E/NR: Light Emitted and Not Received).
The sensor may be defective.
(Remedy 1) Confirm that no dirt adheres to the sensor. Or, it may be necessary to replace the
sensor with a new one because it may be defective.
Before replacing the sensor, contact our service personnel for some advice.
430205 NOZZLE POSITION THE SELECTED NOZZLE LEVEL POSITION SENSOR WAS
NOT ACTIVATED.; BPH15, 16
(Cause 1) The optical beam was not set in the “E/R” or the “E/NR” condition due to dirt on the
sensor. (E/R: Light Emitted and Received, E/NR: Light Emitted and Not Received).
The sensor may be defective.
(Remedy 1) Press the [RETURN] button to cancel the error display and check that no dirt
adheres to the sensor.
430206 NOZZLE POSITION THE UNSELECTED NOZZLE WAS ERRONEOUSLY POSI-
TIONED.; BPH17, BPH18
(Cause 1) The optical beam was not set in the “E/R” or the “E/NR” condition due to dirt on the
sensor. (E/R: Light Emitted and Received, E/NR: Light Emitted and Not Received).
The sensor may be defective.
(Cause 2) This error occurs when the nozzle almost comes off at Station #8 and touches the
component discharge plate.
(This error occurs during automatic or manual operation.)
(Remedy 1) Confirm that no dirt adheres to the sensor. Or, it may be necessary to replace the
sensor with a new one because it may be defective.
Before replacing the sensor, contact our service personnel for some advice.
(Remedy 2) Check the head at Station #8. Subsequently, perform the reverse rotation opera-
tion to move the head back toward the front side of the machine. Then, insert the
nozzle deep inside.
01 10-003 2-106 AFO01ETRP
3.3 Error IDs and Remedial Procedures
Error ID Item Description
430301 Head No. The head no. Detection sensor was not activated.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
430401 X/Y Table P.C.B. was dislodged while the X/Y table was in motion.
430402 X/Y Table P.C.B. was dislodged while the X/Y table was in motion.
(Cause 1) The P.C.B. is trapped on the X/Y table.
The P.C.B. pilot pin, the positioning lever, and the P.C.B. support pin are not located
at their regular positions.
(Remedy 1) Check how the P.C.B. pilot pin, the positioning lever, and the P.C.B. support pins
are attached.
430403 X/Y Table X/Y chute has gone up while X/Y table was in motion.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
01 10-003 2-107 AFO01ETRP
3.3 Error IDs and Remedial Procedures