CX200-4(Maint).pdf - 第281页
Recognition Error ID Item Description 10 03 0 14002 ---- Error in Lighting System (Front Lighting 3) Failed in T eaching Operation for Assumed Bright- ness. (Cause 1) The lighting system may be abnormal. (Remedy 1) Conta…

Recognition Error ID Item Description
10 03 0 11002 ---- Error in Lighting System (Back Lighting)
Failed in Teaching Operation for Assumed Bright-
ness.
(Cause 1) The lighting system may be abnormal.
(Remedy 1) Contact our service personnel for details.
10 03 0 12001 ---- Error in Lighting Intensity Data (Front Lighting 1)
The data has exceeded the specified range.
(Cause 1) The longevity of the lamp might have ended.
(Remedy 1) Replace the lamp with a new one.
Or, contact our service personnel for some advice.
10 03 0 12002 ---- Error in Lighting System (Front Lighting 1)
Failed in Teaching Operation for Assumed Bright-
ness.
(Cause 1) The lighting system may be abnormal.
(Remedy 1) Contact our service personnel for details.
10 03 0 13001 ----- Error in Lighting Intensity Data (Front Lighting 2)
The data has exceeded the specified range.
(Cause 1) The longevity of the lamp might have ended.
(Remedy 1) Replace the lamp with a new one.
Or, contact our service personnel for some advice.
10 03 0 13002 ---- Error in Lighting System (Front Lighting 2)
Failed in Teaching Operation for Assumed Bright-
ness.
(Cause 1) The lighting system may be abnormal.
(Remedy 1) Contact our service personnel for details.
10 03 0 14001 ---- Error in Lighting Intensity Data (Front Lighting 3)
The data has exceeded the specified range.
(Cause 1) The longevity of the lamp might have ended.
(Remedy 1) Replace the lamp with a new one.
Or, contact our service personnel for some advice.
01 10-003 2-191 AFO01ETRP
4.3 Recognition Error IDs and Remedial Procedures

Recognition Error ID Item Description
10 03 0 14002 ---- Error in Lighting System (Front Lighting 3)
Failed in Teaching Operation for Assumed Bright-
ness.
(Cause 1) The lighting system may be abnormal.
(Remedy 1) Contact our service personnel for details.
10 04 0 ***** ---- Error in Gain and Level Teaching Operation.
(Cause 1) The vacuum nozzle or the diffusion board is dirty.
(Remedy 1) Wipe the vacuum nozzle end or the tapered area with a soft cloth.
10 05 0 12001 ---- Specified Number of Dots Not Found during Cam-
era Angle Teaching Operation.
(Cause 1) The jig is not correctly set.
(Cause 2) A foreign substance adheres to the jig.
(Remedy 1) Set the jig correctly.
(Remedy 2) Wipe the jig surface with a soft cloth.
01 10-003 2-192 AFO01ETRP
4.3 Recognition Error IDs and Remedial Procedures

4.3.6 Component Recognition Lighting Lamp Burnout Errors
AA BB C DDDDD
Detail Code
Secondary Error Classification (0)
Primary Error Classification (0)
Classification (13) of Recognition Functions
Table 4B15
Recognition Error ID Item Description
13 00 0 00000 ---- The lamp for back lighting has blown in the com-
ponent recognition lighting unit.
13 00 0 00001 ---- The lamp for Front Lighting 1 (Ring 1) has blown in
the component recognition lighting unit.
13 00 0 00002 ---- The lamp for Front Lighting 2 (Coax) has blown in
the component recognition lighting unit.
13 00 0 00003 ---- The lamp for Front Lighting 3 (Ring 2) has blown in
the component recognition lighting unit.
(Cause 1) The lamp of the component recognition lighting device was burnt out.
(Remedy 1) Replace the lamp with a new one.
After the replacement, perform the teaching operation required for com-
ponent recognition.
01 10-003 2-193 AFO01ETRP
4.3 Recognition Error IDs and Remedial Procedures