CX200-4(Maint).pdf - 第264页

Recognition Error ID Item Description 01 39 3 20004 Error in “Component Library Front ltg algo” Data ---- 01 39 3 20005 Error in “Component Library Back ltg algo” Data ---- (Cause) Wrong parameters are set. (Remedy) Set …

100%1 / 299
Recognition Error ID Item Description
01 39 3 14112 Error in “Component Library Elctd Dim1” Data ----
01 39 3 14113 Error in “Component Library Elctd Dim2” Data ----
01 39 3 14213 Error in “Component Library Elctd Gp Posn X or ----
Y” Data
01 39 3 14214 Error in “Component Library Elctd Col Pitch” ----
Data
01 39 3 14215 Error in “Component Library Row Pitch” Data ----
01 39 3 14216 Error in “Component Library Elctd # of Cols” ----
Data
01 39 3 14217 Error in “Component Library Elctd # of Rows” ----
Data
01 39 3 14221 Error in “Component Library Elctd Missing Elctd ----
No” Data
01 39 3 14231 Error in “Component Library Elctd Missing Std ----
Col” Data
01 39 3 14232 Error in “Component Library Elctd Missing Std ----
Row” Data
01 39 3 14233 Error in “Component Library Elctd # of Missing ----
Cols” Data
01 39 3 14234 Error in “Component Library Elctd # of Missing ----
Rows” Data
(Cause) Wrong parameters are set.
(Remedy) Set correct parameters.
01 39 3 20003 “Component Library Recog Level” ----
Not Supported!
(Cause) The data is not supported.
(Remedy) Set the supported data.
01 10-003 2-174 AFO01ETRP
4.3 Recognition Error IDs and Remedial Procedures
Recognition Error ID Item Description
01 39 3 20004 Error in “Component Library Front ltg algo” Data ----
01 39 3 20005 Error in “Component Library Back ltg algo” Data ----
(Cause) Wrong parameters are set.
(Remedy) Set correct parameters.
01 39 3 20007 “Component Library View Range Set” Not ----
Supported!
01 39 3 22001 “Component Library Polarity Detn” ----
Not Supported!
01 39 3 22002 “Component Library Polarity Inspection Method” ----
Not Supported!
01 39 3 22003 “Component Library Polarity Detn Inspection ----
Pos X or Y” Not Supported!
01 39 3 22004 “Component Library Polarity Detn Inspection ----
Range” Not Supported!
01 39 3 23001 “Component Library Upper/Lower Surface Detn” ----
Not Supported!
(Cause) The data is not supported.
(Remedy) Set the supported data.
01 39 3 24102 Error in “Component Library Mold Size ----
Tolerance X or Y” Data
(Cause) Wrong parameters are set.
(Remedy) Set correct parameters.
01 39 3 24201 “Component Library Outward Length Detn” Not ----
Supported!
(Cause) The data is not supported.
(Remedy) Set the supported data.
01 10-003 2-175 AFO01ETRP
4.3 Recognition Error IDs and Remedial Procedures
Recognition Error ID Item Description
01 39 3 24202 Error in “Component Library Outward Length Tol” ----
Data
(Cause) Wrong parameters are set.
(Remedy) Set correct parameters.
01 39 3 25101 “Component Library Lead Width Detn” Not ----
Supported!
(Cause) The data is not supported.
(Remedy) Set the supported data.
01 39 3 25102 “Component Library Lead Posn (Latl Dir) Detn” ----
Not Supported!
(Cause) Wrong parameters are set.
(Remedy) Set correct parameters.
01 39 3 25201 “Component Library Lead Posn (Latl Dir) Detn” ----
Not Supported!
(Cause) The data is not supported.
(Remedy) Set the supported data.
01 39 3 25202 Error in “Component Library Lead Posn ----
(Latl Dir) Tol” Data.
(Cause) Wrong parameters are set.
(Remedy) Set correct parameters.
01 10-003 2-176 AFO01ETRP
4.3 Recognition Error IDs and Remedial Procedures