HS50_advance_level 2.pdf - 第117页

Stud ent Gu ide HS-5 0 Adva nced II 07/2 002 Ed ition 4 Pneum atic 15  7 DSH &XWWHU  3 &%6 WRSS HU +5 bar from main pneumatic unit +24V +24V in out in out +5 bar fr om m ain pneumatic unit +24V in out oth…

100%1 / 431
07/2002 Edition Student Guide HS-50 Advanced II
4 Pneumatic
14
 7\SLFDO9DFXXP5HIHUHQFH5XQDQG9DFXXP9DOXHV
NOTE
Component on nozzle (30 mbar, tighter than open) eject in ejection position. No component on
nozzle (nozzle value almost on open) -> optimized pick - up process. Closed vacuum, new pick -
up at once
Seg.
1
Seg.
2
Seg.
3
Seg.
4
Seg.
5
Seg.
6
Seg.
7
Seg.
8
Seg.
9
Seg.
10
Seg.
11
Seg.
12
TYP
914
TYP
914
TYP
914
TYP
914
TYP
914
TYP
914
TYP
914
TYP
914
TYP
914
TYP
914
TYP
914
TYP
914
Vacuum open
Reference run -702, -703, -700, -698,
-
700, -698,
-
700, -698,
-
700,
-
701, -703, -701,
Vacuum open
measured with
component -800, -798, -805, -816,
-
720,
-
810, -730,
-
810,
-
805, -811, -799,
20% vacuum-dif-
ference 32 32 32 33 32 32 33 32 32 32 32
Vacuum closed
measured -863, -864, -863, -863,
-
863,
-
863, -863,
-
863,
-
863, -863, -863,
Vacuum closed
reference run -863, -864, -863, -863,
-
863, -832,
-
863, -863,
-
863,
-
863, -863, -863,
Student Guide HS-50 Advanced II 07/2002 Edition
4 Pneumatic
15
 7DSH&XWWHU
 3&%6WRSSHU
+5 bar from main
pneumatic unit
+24V+24V
in
out
in
out
+5 bar from main
pneumatic unit
+24V
in
out
other
stopper
in the
machine
07/2002 Edition Student Guide HS-50 Advanced II
4 Pneumatic
16
 1R]]OH&KDQJHU
 &RPSRQHQW7DEOH
+5 bar from main
pneumatic unit
Double effect cylinder
Valve 5/2
+24V
in
out
+24V
in
out
nozzle changer 1 nozzle changer 2
+5 bar from main
pneumatic unit
in
out
next feeder table