07/2002 Editio n Student G uide HS -50 Advanc ed II 14 Conveyor System 16 Key to A PCB trans port direc tion 1a - 1d) Li fting table 1 - 4 2 ) Basic con structi on of mount ing pl ate 3) Lifting table motor (2 eac h per …

100%1 / 431
Student Guide HS-50 Advanced II 07/2002 Edition
14 Conveyor System
15
07/2002 Edition Student Guide HS-50 Advanced II
14 Conveyor System
16
Key to
A PCB transport direction
1a - 1d) Lifting table 1 - 4 2) Basic construction of mounting plate
3) Lifting table motor
(2 each per conveyor 1 / 2)
4) Guide pillar
5) Conveyor mount 1 (movable side) 6) Conveyor mount 2 (fixed side)
7) Adapter 1 width adj. system 8) Adapter 2 for width adj. system
9) Linear guide for width adj. system 10) Limit switch, minimum PCB conveyor width
11) Limit switch, maximum PCB conveyor
width
12) Proximity switch "lifting table, down", place-
ment area 1/2
13) Proximity switch "lifting table, up", place-
ment area 1/2
14) Guide tube
15) Drive unit for width adjustment system,
conveyor 1 or 2
16) Toothed belt 10T2.5/245 for
drive for width adj. system
17) Recirculating spindle 18) Synchronizing belt Breco 12 T5/2855
welded
19) PCB support 20) PCB support (for large PCB)
Student Guide HS-50 Advanced II 07/2002 Edition
14 Conveyor System
17
Key to
*) The assembly "Sonar proximity switch" includes the sensing head with amplifier and cable.
1) , tiltable, for sonar proximity switch amplifier 2) Hexagonal nut M5
3) Hex socket head cap screws M5 x 70 4) Sonar prox. switch, output, conveyor 1 *)
5) Sonar prox. switch, output, conveyor 2 *) 6) Sonar prox.switch for placement area 2 *)
7) Sonar proximity switch for placement
area 3 *)
8) Sonar prox. switch, intermediate belt, con-
veyor 1 *)
9) Sonar prox. switch, intermediate belt, con-
veyor 2*)
10) Sonar prox. switch for placement area 3 *)
11) Sonar prox. switch for placement area 4*) 12) Sonar proximity switch, input,
conveyor 1 *)
13) Sonar prox. switch, input, conveyor 2 *) 14) Potentiometer for calibration
14) Connection for sonar proximity switch
cable (from sensing head)
16) Connection of amplifier cable (connected
at "PCB Conveyor Control PCB1 / PCB2 )