00196378-0102_UM X-Feeder_EN.pdf - 第21页
Overview of X Feeder Modules Structure of the SIPLACE X-Series Tape Feeder Modules Functions and Operating Controls User Manual X Feeder M odules SIPLACE Family 21 8 mm X tape feeder module - rear view Legend (1) Entry t…

Overview of X Feeder Modules
Functions and Operating Controls Structure of the SIPLACE X-Series Tape Feeder Modules
20 User Manual X Feeder Modules SIPLACE Family
8 mm X tape feeder module - front view
Legend
(1) Locking roll for fixing the feeder mod-
ule on the component table
(2) EDIF (energy and data interface)
(3) Front centering pin (4) Lever for raising the pickup window in
order to thread in and remove the
component tape
(5) Pickup window (6) Exit from the empty tape duct
(7) Setting of the foil tension (8) Foil rocker
(9) Tape disposal rolls (10) Rear centering pin
(11) Type plate

Overview of X Feeder Modules
Structure of the SIPLACE X-Series Tape Feeder Modules Functions and Operating Controls
User Manual X Feeder Modules SIPLACE Family 21
8 mm X tape feeder module - rear view
Legend
(1) Entry to the empty tape duct with tape
spring
(2) Removal flap to the foil container
(3) Integrated blade for cutting off the
cover foil
(4) Removal handle, engaged
(5) Operator panel (6) Drive motor for foil removal
(7) Drive motors for the tape conveyor (8) Rotary valve for removing compo-
nents
(9) Front sliding guide (10) Rear sliding guide
(11) Graphical representation of the pick-
up position in relation to the compo-
nent size

Overview of X Feeder Modules
Functions and Operating Controls Display at the Tape Feeder Modules
22 User Manual X Feeder Modules SIPLACE Family
3.1.2 Display at the Tape Feeder Modules
3.1.2.1 LED Display on the 2x8 mm Tape Feeder Modules
Status display
▪ If the status display lights up green, the respective track of the feeder module is ready-to-operate
and needed for the current placement job. This status display also lights up green, if no placement
job has been assigned yet.
▪ If the status display is orange, this indicates that a warning has been issued.
▪ If the status display lights up red, an error has occurred. In the case, the pitch display indicates the
error source.
▪ If the status display remains dark, the feeder module is not needed for the current placement job.
Definitions of Terms Describing the Operating and Display Functions
Operator panel of the 2x8 mm tape feeder modules
Legend
1. Pitch display (LEDs) right
2. Track display right
3. Track change button
4. Forwards button
5. Backwards button
6. Foil button
7. Set button
8. Status display (2x)
9. Track display left
10. Pitch display (LEDs) left
The X feeder modules are equipped with 10 LEDs
(1, 2, 9 and 10) for indicating the operating states and
one multi-colored status display for each track (8).
Display The display indicates a specific status (e. g. the currently set pitch or the se-
lected track) and consists of several LEDs.
LED Abbreviation for "light emitting diode". LED designates a single element in a
display (e. g. left track "L").
Short press of the button The button is pressed and released within 0.75 seconds.
Long press of the button The button is being pressed more than 0.75 seconds.
Fast flashing
The LED is on and off for 0.15 second each, i. e., it flashes 3.3 times per
second.
Slow flashing
The LED is on and off for 0.45 second each, i. e., it flashes approx. once per
second.
Running light forwards The LEDs 1, 2, 4 and 8 of the pitch display light up one after another and
then they are all off. After that this sequence is repeated.
Running light backwards The LEDs 8, 4, 2 and 1 of the pitch display light up one after another and
then they are all off. After that this sequence is repeated.