00196378-0102_UM X-Feeder_EN.pdf - 第61页
Operating Tape Feeder Modules Removing the Tape Setting Up the Feeder Module User Manual X Feeder M odules SIPLACE Family 61 4.2.7.2 Removing the Tape on 8 -88 mm Feeder Modules Removing the tape A - Removal of tape with…

Operating Tape Feeder Modules
Setting Up the Feeder Module Removing the Tape
60 User Manual X Feeder Modules SIPLACE Family
Feeder module in status: Foil tensioned
►(1) Initial status: The tear down procedure is enabled by long pressing the Backwards button.
►(2) Tear down procedure is enabled: After 0.75 seconds the pitch display indicates by a backwards
running light that the tear down procedure is enabled. The Backwards button is now released. After
that the foil rocker is relaxed within 5 seconds (cutting off the foil or relaxing the foil disposal rolls). If
the foil rocker is still tensioned after 5 seconds, the tear down procedure is cancelled.
►Track is torn down: The tear down procedure is completed and the pitch display returns to its initial
status.
Feeder module in status: Torn foil
►(1) Initial status: The error state "Torn foil" is indicated by a red status display and slow flashing of
LED 2 of the pitch display. The tear down procedure is enabled by long pressing the Backwards
button.
►Error "Torn foil" is deleted: After 0.75 seconds the error state "Torn foil" is deleted and the track is
torn down. The status display turns green if the feeder module is needed for the current placement
job and if there is no other error.
►The Backwards button is now released.
CAUTION
Risk of placement head crash
After performing a tear down, make sure that there are no tape or foil residues in the feeder
module pickup area, as the placement head could get caught in these.
►Remove all tape or foil residues.
CAUTION
Risk of placement head crash
After performing a tear down, make sure that there are no tape or foil residues in the feeder
module pickup area, as the placement head could get caught in these.
►Remove all tape or foil residues.

Operating Tape Feeder Modules
Removing the Tape Setting Up the Feeder Module
User Manual X Feeder Modules SIPLACE Family 61
4.2.7.2 Removing the Tape on 8 -88 mm Feeder Modules
Removing the tape
A - Removal of tape with energy supply
►(1) Cut off the cover foil at the foil removal slot.
►(2) Press the "Backwards" key. The tape is moved out of the toothed wheel and lies free.
►(3) Pull the tape backwards out of the feeder module.
B - Removal of tape without energy supply
►(1) Cut off the cover foil at the foil removal slot.
►(2) Press the lever forwards until the stop.
►(3) Pull the tape backwards out of the feeder module.
Tearing down the feeder module
►(1) Press the Backwards button for at least 5
seconds.
►(2) After a successful tear down the display issues the
message Reel removed torn down.

Operating Tape Feeder Modules
Using the Operator Panel Overview of the Operator Panels
62 User Manual X Feeder Modules SIPLACE Family
4.3 Using the Operator Panel
4.3.1 Overview of the Operator Panels
4.3.1.1 Overview of the Operator Panel for 2x8 mm Feeder Modules
Colors of the status display
The status display uses different colors to indicate the current state of the feeder module.
1. LED 8 mm pitch left track
2. LED 4 mm pitch left track
3. LED 2 mm pitch left track
4. LED 1 mm pitch left track
5. LED L left track active
6. Track change button
7. Forwards button
8. Backwards button
9. Foil button
10. Set button
11. LED 8 mm pitch right track
12. LED 4 mm pitch right track
13. LED 2 mm pitch right track
14. LED 1 mm pitch right track
15. LED R right track active
16. Status display left track
17. Status display right track
Display Meaning
Is off The feeder is not in use.
Lights up green The feeder module is used and ready-to-operate.
* The feeder module is set up with the correct components.
Lights up red Error
The feeder module was deactivated by the station.
Lights up orange Usually indicates a warning (see also "5.1 Messages for 2x8 mm Feeder Mod-
ules" [ ➙ 79])
* The feeder module immediately needs more components.
* This information is only displayed if the line is equipped with a SIPLACE setup verification software.