00196378-0102_UM X-Feeder_EN.pdf - 第90页
Messages Messages for 8 - 88 mm Feeder Modules Messages From Process 90 User Manual X Feeder Modules SIPLACE Family 5.2.2.4 Scan OK 5.2.2.5 Scan Error 5.2.2.6 Fill level Too Low 5.2.2.7 Splice Sensor 5.2.2.8 Vision Error…

Messages
Messages From Process Messages for 8 - 88 mm Feeder Modules
User Manual X Feeder Modules SIPLACE Family 89
5.2.1.26 EEPROM Data Error
5.2.1.27 Scan Request
5.2.2 Messages From Process
5.2.2.1 Introduction
The following messages are only shown by the feeder module. The display text itself is generated by the
station computer and is then transmitted via the CAN bus to the LCD display of the feeder module. The
error source is therefore not in the feeder module but usually in the placement machine state. For exam-
ple, pickup or Vision errors, which affect the component of a particular track, will be displayed on the
feeder module for that track. The following table shows the LCD display text, the color and mode of the
status display, the cause and troubleshooting measures.
5.2.2.2 Not Verified
5.2.2.3 Scan Barcode
LCD, de:
LCD, en:
EEP-DataErr
EEP-DataErr
Status display: red
Cause: The data back-up in the EEPROM was not carried out completely
Solution: Remove the tape. Acknowledge the error with the SET button. Acknowledge the
prompt for a reference run with the yellow button.
If the message continues to appear, you will need to replace the control board or
the drive.
Comments: Since the position of the drive is stored in the EEPROM, a reference run is
necessary in these cases.
LCD, de:
LCD, en:
Scan Anford.
Scan Request
Status display: - - -
Cause: The request to perform scanning has been sent by the feeder module to the MC
(Machine Controller).
Solution: - - -
Comments: After the grey SET button has been pressed (1 sec.) the display shows the
Scan Anford. / Scan Request message for approx. 2 sec. to indicate that
the feeder module has sent a request for barcode scanning to the MC. If a barcode
system is active, the MC will then send the Scan Barcode display text to the
feeder module.
From version 1.24
LCD, de:
LCD, en:
NichtGeprueft
Not verified
Status display:
Cause: The tape has been inserted but the barcode has not yet been scanned.
Solution: Scan the barcode.
Comments: This message is only shown if a barcode system has been installed and is active.
LCD, de:
LCD, en:
Scan Barcode
Scan Barcode
Status display:
Cause: The barcode still needs to be scanned.
Solution: Scan the barcode.
Comments: - - -

Messages
Messages for 8 - 88 mm Feeder Modules Messages From Process
90 User Manual X Feeder Modules SIPLACE Family
5.2.2.4 Scan OK
5.2.2.5 Scan Error
5.2.2.6 Fill level Too Low
5.2.2.7 Splice Sensor
5.2.2.8 Vision Error
LCD, de:
LCD, en:
Scan OK
Scan OK
Status display:
Cause: Barcode scanning was successful.
Solution: - - -
Comments: - - -
LCD, de:
LCD, en:
Scan Fehler
Scan Not OK
Status display:
Cause: Barcode scanning was not successful.
Solution: Scan the barcode again.
Comments: Check the quality of the barcode label.
LCD, de:
LCD, en:
Fuell. Niedrig
Low Filling
Status display:
Cause: Warning issued when fill level is too low
Solution: Splice on new component reel and update fill level.
Comments: This message is only shown if a component level indicator has been installed and
is active.
LCD, de:
LCD, en:
SpleissSensor
SpliceSensor
Status display:
Cause: Warning issued when the splice sensor is missing.
Solution: Provide a feeder module with splice sensor or switch off the component level indi-
cator in the station software, if this is not being used.
Comments: The splice sensor in a feeder module is only required by the placement machine if
a component on this track is subject to a component level indicator or traceability
function.
LCD, de:
LCD, en:
VisionFehler
Vision Error
Status display:
Cause: The component on this track has not been correctly recognized by the image
processing tool or the component is defective.
Solution: Check the geometry of the component with the Vision data
Comments: This requires an exact analysis of the pickup process, as this error message could
have several causes.

Messages
Messages From Process Messages for 8 - 88 mm Feeder Modules
User Manual X Feeder Modules SIPLACE Family 91
5.2.2.9 Pickup Error
5.2.2.10 Target Directory Full
5.2.2.11 External Deactivation
5.2.2.12 Refill
5.2.2.13 Wrong Type
LCD, de:
LCD, en:
Abhol Fehler
Pickup Error
Status display:
Cause: The component on this track was not correctly picked up by the placement head.
The track was disabled.
Solution: Check the nozzle vacuum.
Comments: This requires an exact analysis of the pickup process, as this error message could
have several causes.
LCD, de:
LCD, en:
Verz. Voll
Target Full
Status display:
Cause: The data folder (spool), for an external operating data recording system, is full.
Unable to save Traceability or GEM data.
Solution: This message can only be reset in the external system (HOST).
Comments: - - -
LCD, de:
LCD, en:
Extern Deak.
Extern Deac.
Status display:
Cause: The track was disabled externally (e.g. through setup verification).
Solution: The track needs to be re-enabled by the external system.
Comments: - - -
LCD, de:
LCD, en:
Nachfuellen
Refill
Status display:
Cause: The track has been disabled because a deactivation threshold was reached.
Solution: Splice on new components for the relevant track (refill trays) and set the track to
"full".
Comments: A warning threshold has been exceeded e.g. by the level checker.
LCD, de:
LCD, en:
Falscher Typ
Wrong Type
Status display:
Cause: A different feeder module type is set in the programming system to that set in the
machine.
Solution: Correct the feeder module type or change the current setup in the programming
system.
Comments: The machine can recognize a feeder module at the location. However, this does
not match that specified in the current setup.