00197295-01_UM_D4i_SR605_EN.pdf - 第208页
5 Tasks for the operating personnel User manual SIPLACE D4i 5.8 Avoiding track errors From software version SR.605.03 SP2 10/2012 EN edition 208 5.8.3 Component coordinate system and pick-up angle 5 Fig. 5.8 - 1 Position…

User manual SIPLACE D4i 5 Tasks for the operating personnel
From software version SR.605.03 SP2 10/2012 EN edition 5.8 Avoiding track errors
207
5.8 Avoiding track errors
5.8.1 General
→ Make sure that the areas around the feeder modules are clean and that there are no loose
components in the feeder area or under the feeder modules.
→ Ensure that the supporting surfaces of the feeder modules, and particularly the magnetic rails
of the component tables, are clean and level.
→ Refill promptly with components.
→ Splice the tapes early. This generally means that you are to prepare the splicing material
when there is still approximately 1.5 m of tape on the reel.
→ Handle the feeder modules carefully when you insert them into or remove them from the com-
ponent table as these are high-precision devices.
→ Close the pick-up window on the feeder module as it could easily be damaged if you leave it
open.
→ Check that the pick-up position is set correctly for the components on the S feeder modules.
→ Check that the S feeder module plugs are connected to the right sockets.
5.8.2 Avoiding track errors with the tape container
→ Insert the separating plates correctly (see Fig. 5.5 - 2, page 201).
→ Tape reels with a diameter of 15" (381 mm) or more should be stored on spindles.
→ When using type 3 x 8 mm S feeder modules make sure to use the second level reel holder
for the middle tape reel (see Section 3.10.7
, page 139).

5 Tasks for the operating personnel User manual SIPLACE D4i
5.8 Avoiding track errors From software version SR.605.03 SP2 10/2012 EN edition
208
5.8.3 Component coordinate system and pick-up angle
5
Fig. 5.8 - 1 Position of the component and its pick-up angle
Special
component
Stick
magazine:
Chip-
components
with polarity
0402
2220
The anode must be
aligned with the +X
coordinate.
Package form Coordinate system
Position in the feeder module
Pick-up angle/
nozzle angle
Tape:
SOT 23
Stick
magazine:
Tape:
Tape:
SO-IC
DIL-IC
SOT 194
Tape:
Holes
Y
X
Y
X
Y
X
Y
X
Y
X
90°
90°
0°
90°
-90°
0°

User manual SIPLACE D4i 5 Tasks for the operating personnel
From software version SR.605.03 SP2 10/2012 EN edition 5.9 Refilling components
209
5.9 Refilling components
The online help contains information on refilling components with and without barcodes.
→ With tape feeder modules, make sure that you always splice on a new tape early enough so
that the feeder modules do not run out of components.
→ However, do not splice the tapes too early because if you wind the tape onto the new reel
after splicing the end of the old tape, the reel with the new tape may be overfilled. The tape
could then slip off the reel and become tangled. Under certain circumstances, this could
cause pick-up errors and prolonged down times.
→ Always insert spindles when using tape reels of 15" (381 mm) and larger (see Fig. 5.5 - 3
,
page 202
) and make sure that the separating plates are inserted correctly (see Fig. 5.5 - 2,
page 201
).