Maintenance Manual.pdf - 第42页
RL1 31 MAINTENANCE MANUAL 2.5 Saf et y Functi ons DA8ME C-10-050- A0 2.5- 1 2.5. Safety Functions DA8ME C-10-050-A0 2.5.1 Out l ine of Safety Functions The saf et y f unction hav e been des i gned on saf et y standar ds.…

RL131
MAINTENANCE MANUAL
2.4 Safety Standards
DA8MEC-10-040-A0
2.4-2

RL131
MAINTENANCE MANUAL
2.5 Safety Functions
DA8MEC-10-050-A0
2.5-1
2.5. Safety Functions
DA8MEC-10-050-A0
2.5.1 Outline of Safety Functions
The safety function have been designed on safety standards. The following have been prepared.
Safety functions types (Sudden stop and 1 block stop system).
Safety Switch types
Emergency Stop
Interlock Stop
Over Travel Stop
2.5.2 Emergency Stop
Pressing the emergency stop switch does not suspend the supply from all power source.
To restart machine, reset the emergency stop switch and press <START>.
2.5.3 Interlock Stop
Opening a safety cover will turn on the sensor and stop the machine.
To restart machine, close the safety cover to turn off the safety interlock switch, and press <START>.
Safety Stop Function
This function, with the protective cover and the safety stop circuit, is designed for securing safety.
When the interlock stop switch operates, all axes stop immediately.
2.5.4 Over Travel Stop
When the travel distance of the X, Y, or Z axis is too long, or to prevent any dangers from occurring, there is
a limit switch, mechanically built-in and placed to aid the limit detection of the photoelectric sensor.

RL131
MAINTENANCE MANUAL
2.5 Safety Functions
DA8MEC-10-050-A0
2.5-2
2.5.5 Safety Switch Arrangement
80 Inputs
XSL
YSL
IL3
ES2
IL1
ES1
IL2
ES4
IL7
IL11
IL10
IL6
IL9
IL8
ES3
IL5
IL4