00191017-01.pdf - 第556页

17.4 Set-Up Generation User ’s Manual Line Computer UNIX 17.4.3 Manual Set-Up Adjustment Software V ersion 403.xx Edition 06/97 17 - 58 FILE Save FILE Quit continu ed from pa ge 17-56 Allocat ing wa ffle-pa ck tray to Wa…

100%1 / 589
User’s Manual Line Computer UNIX 17.4 Set-Up Generation
Software Version 403.xx Edition 06/97 17.4.3 Manual Set-Up Adjustment
17 - 57
To open the Set-Up Editor/Feeder Part Editor, proceed as follows:
1. On the desktop click on the feeder part of the respective station, here:
right feeder part of Siplace_80S
.
The file selection window for set-up selection is opened.
2. Click on the set-up, here:
Examples01.ar
and click on the
OK
button.
The Set-Up Editor/Feeder Part Editor for this feeder part is opened.
To delete a feeder, proceed as follows:
3. Activate the Delete icon .
4. Click on the feeder that is to be deleted, here:
FD~S_G_12
on track
97
.
A dialog box appears.
5. In the dialog box click on the
OK
button.
The feeder is deleted, the dialog box is closed.
6. If required, delete other feeders analogously, here:
FD~S_G_12
on track 103
.
To allocate a feeder to a track, (here: linear feeders with module), proceed as follows:
7. Activate the Create icon .
8. Click on the
°Feeder list
option on the
SERVICES
menu.
The feeder list is opened.
9. Activate the Module icon .
A listing of all modules is displayed.
10. Click on a module, here:
MD~S_L_10_15
.
11. Click on a track, here:
track
97.
The module is set up on the track.
12. Set up the same module on track 103 analogously.
13. Click on the
°Feeder list
option on the
SERVICES
menu.
The feeder list is opened.
14. On the Feeder list activate the Feeder icon .
A listing of all feeders is displayed.
15. Click on a feeder, here:
FD~S_LIN_15
.
16. Click on an area of one of the modules.
The feeder is set up in this area.
17. Click on the
°Feeder list
option on the
SERVICES
menu.
The feeder list is opened.
18. Click on a feeder, here:
FD~S_LIN_15
.
19. Click on the other area on the module.
The feeder is set up in this area, the feeder list is closed.
20. Set up the second module analogously.
To allocate a component to a feeder, proceed as follows:
21. Click on the component in the component list, here:
Comp6
.
22. Click on the compartment (division) of a feeder.
The component Comp6 is allocated to the compartment and the component name is displayed on the
right hand side.
23. Allocate components to the other compartments of the feeder analogously.
17.4 Set-Up Generation User’s Manual Line Computer UNIX
17.4.3 Manual Set-Up Adjustment Software Version 403.xx Edition 06/97
17 - 58
FILE
Save
FILE
Quit
continued from page 17-56
Allocating waffle-pack
tray to Waffle-Pack
Changer
Saving set-up
Opening Set-Up Editor/
WPC Editor
Adjusting vibration time
and pick-up angle
continued on page 17-60
Setting up feeders
Setting up waffle-pack trays
Defining waffle-pack
tray
User’s Manual Line Computer UNIX 17.4 Set-Up Generation
Software Version 403.xx Edition 06/97 17.4.3 Manual Set-Up Adjustment
17 - 59
To adapt the vibration time and the pick-up angle, proceed as follows:
24. Activate the Select icon.
25. Click on a compartment of a feeder.
26. Click on the
Packaging box
option on the
SERVICES
menu.
The Packaging Editor is opened.
27. Click on the
Pick-up ang.
editing field and enter the new pick-up angle, here:
90
degrees
.
28. Click on the
Vibrat. time
editing field and enter the new vibration time, here:
600 ms
.
29. Click on the
Quit
option on the
FILE
menu.
The Packaging Editor is closed.
To save the set-up, proceed as follows:
30. Click on the
Save
option on the
FILE
menu.
The data are saved.
31. Click on the
Quit
option on the
FILE
menu.
The Set-Up Editor/Feeder Part Editor is closed.
To open the Set-Up Editor/WPC Editor, proceed as follows:
32. On the desktop click on the Waffle-Pack Changer.
The file selector box for the set-up selection is opened.
33. Click on the set-up, here:
Examples01.ar
and click on the
OK
button.
The Set-Up EditorWPC Editor is opened.
To allocate a waffle-pack tray to a level of the Waffle-Pack Changer:
34. Activate the Create icon.
35. In the Levels display area click on a level, here:
Level1
.
36. Click on the
°Feeder list
option on the
SERVICES
menu.
The feeder list is opened.
37. Activate the waffle-pack tray carrier icon.
A list with all waffle-pack tray carriers is opened.
38. Click on a waffle-pack tray carrier, here:
WC~S_TYP_1
.
39. Click on the symbol of the Waffle-Pack Changer.
The waffle-pack tray carrier is set up at the appropriate level.
40. Click on the
°Feeder list
on the
SERVICES
menu.
The feeder list is opened.
41. On the feeder list activate the Waffle-pack tray icon.
A window containing a waffle-pack tray with the spacing 1x1 is opened.
42. Click on the waffle-pack tray on the text line.
43. Click on the waffle-pack tray carrier in the display.
The waffle-pack tray is set up on the waffle-pack tray carrier.
To define a waffle-pack tray, proceed as follows:
44. Click on the blue pick-up area of the waffle-pack tray.
45. Click on the
Packaging box
option on the
SERVICES
menu.
The Packaging Editor is opened.
46. Enter the dimensions of the waffle-pack tray in the editing fields, see
Fig. 17.4.1
on
page 17-
61
.