Horizon UserManualV6.pdf - 第279页
Inspect 1. Select Inspect Site . Edit Global Edit Limits Delete Site Next Site Previous Site Edit Site Inspect Site Exit NOTE Delete site,next site and previous site may not be displayed if other sites do not exist. The …

5. Select Exit.
Learn
Board
ReLearn
Screen
Auto
Learn
Next Previous Incr. Decr.
Exit
6. Select Exit.
Add
Site
Learn
Site
Light
Setup
Next Previous Incr. Decr.
Exit
8.28 User Manual Software Version 6
2Di INSPECTION
2Di SETUP
The site learnt graphics appear around the screen aperture and on the board pads
confirming that the site is learnt. If necessary, adjust the mirror image board site
graphic over the corresponding pad.
Screen site learnt boxBoard site learnt box

Inspect 1. Select Inspect Site.
Edit
Global
Edit
Limits
Delete
Site
Next
Site
Previous
Site
Edit
Site
Inspect
Site
Exit
NOTE
Delete site,next site and previous site may not be displayed if other sites do not
exist.
The following window is displayed:
2. If the screen and board were clean, the maximum blockage, smear area and
minimum paste should all be zero. If readings are incorrect, repeat from
Lighting Setup and re-inspect.
3. Select Exit.
Auto
Scale
Toggle
Paste
Next Previous Save
Image
Exit
4. Select Exit.
Edit
Global
Edit
Limit
Delete
Site
Edit
Site
Inspect
Site
Exit
5. Select Step until the board is printed.
Step
Inspect
Setup
Single Exit
Software Version 6 User Manual 8.29
2Di INSPECTION
2Di SETUP
SITE NAME
Maximum Blockage
Smear Area
Minimum Paste
X Alignment
Y Alignment
Bridging
Minimum Paste Volume
Bridge Warnings
Bridge Alarms
SITE 1
0%
0.0 sq mm
0%
----
----
+10.00mm
0%
0
0
Inspection Results
PASS
PASS
ALARM
INVALID
INVALID
PASS
ALARM
No. Blockage Paste Present Volume AlignX AlignY
1 0% 0% 0% ---- ----
2 0% 0% 0% ---- ----

6. Select Step until inspect setup is displayed.
Step
Single Exit
7. Select Inspect Setup.
Step
Inspect
Setup
Single Exit
8. Select Inspect Site.
Edit
Global
Edit
Limits
Delete
Site
Next
Site
Previous
Site
Edit
Site
Inspect
Site
Exit
The following window is displayed:
NOTE
A reliable paste present reading is made only when the lighting is set correctly.
9. If the board inspection type is set to advanced carry out Steps 9a and 9b. If
the board inspection type is set to none or basic carry out Step 9c.
9a. Select Toggle Paste.
Auto
Scale
Toggle
Paste
Next Previous Save
Image
Exit
NOTE
Selecting toggle paste either shows or hides the paste display overlay onto the
monitor. The toggle paste facility on the board image is only functional with the
board inspection type set to advanced. Toggling paste on the screen is only
available on Horizon and Infinity machines and only with the screen inspect type
set to basic or advanced.
8.30 User Manual Software Version 6
2Di INSPECTION
2Di SETUP
SITE NAME
Maximum Blockage
Smear Area
Minimum Paste
X Alignment
Y Alignment
Bridging
Minimum Paste Volume
Bridge Warnings
Bridge Alarms
SITE 1
0%
0.00 sq mm
94%
+0.007mm
-0.003mm
5.012mm
93%
0
0
Inspection Results
PASS
PASS
PASS
PASS
PASS
PASS
PASS
No. Blockage Paste Present Volume AlignX AlignY
1 0% 94% 93% +0.007 -0.003
2 0% 98% 97% +0.006 -0.002