Horizon UserManualV6.pdf - 第280页
6. Select Step until inspect setup is displayed. Step Single Exit 7. Select Inspect Setup . Step Inspect Setup Single Exit 8. Select Inspect Site . Edit Global Edit Limits Delete Site Next Site Previous Site Edit Site In…

Inspect 1. Select Inspect Site.
Edit
Global
Edit
Limits
Delete
Site
Next
Site
Previous
Site
Edit
Site
Inspect
Site
Exit
NOTE
Delete site,next site and previous site may not be displayed if other sites do not
exist.
The following window is displayed:
2. If the screen and board were clean, the maximum blockage, smear area and
minimum paste should all be zero. If readings are incorrect, repeat from
Lighting Setup and re-inspect.
3. Select Exit.
Auto
Scale
Toggle
Paste
Next Previous Save
Image
Exit
4. Select Exit.
Edit
Global
Edit
Limit
Delete
Site
Edit
Site
Inspect
Site
Exit
5. Select Step until the board is printed.
Step
Inspect
Setup
Single Exit
Software Version 6 User Manual 8.29
2Di INSPECTION
2Di SETUP
SITE NAME
Maximum Blockage
Smear Area
Minimum Paste
X Alignment
Y Alignment
Bridging
Minimum Paste Volume
Bridge Warnings
Bridge Alarms
SITE 1
0%
0.0 sq mm
0%
----
----
+10.00mm
0%
0
0
Inspection Results
PASS
PASS
ALARM
INVALID
INVALID
PASS
ALARM
No. Blockage Paste Present Volume AlignX AlignY
1 0% 0% 0% ---- ----
2 0% 0% 0% ---- ----

6. Select Step until inspect setup is displayed.
Step
Single Exit
7. Select Inspect Setup.
Step
Inspect
Setup
Single Exit
8. Select Inspect Site.
Edit
Global
Edit
Limits
Delete
Site
Next
Site
Previous
Site
Edit
Site
Inspect
Site
Exit
The following window is displayed:
NOTE
A reliable paste present reading is made only when the lighting is set correctly.
9. If the board inspection type is set to advanced carry out Steps 9a and 9b. If
the board inspection type is set to none or basic carry out Step 9c.
9a. Select Toggle Paste.
Auto
Scale
Toggle
Paste
Next Previous Save
Image
Exit
NOTE
Selecting toggle paste either shows or hides the paste display overlay onto the
monitor. The toggle paste facility on the board image is only functional with the
board inspection type set to advanced. Toggling paste on the screen is only
available on Horizon and Infinity machines and only with the screen inspect type
set to basic or advanced.
8.30 User Manual Software Version 6
2Di INSPECTION
2Di SETUP
SITE NAME
Maximum Blockage
Smear Area
Minimum Paste
X Alignment
Y Alignment
Bridging
Minimum Paste Volume
Bridge Warnings
Bridge Alarms
SITE 1
0%
0.00 sq mm
94%
+0.007mm
-0.003mm
5.012mm
93%
0
0
Inspection Results
PASS
PASS
PASS
PASS
PASS
PASS
PASS
No. Blockage Paste Present Volume AlignX AlignY
1 0% 94% 93% +0.007 -0.003
2 0% 98% 97% +0.006 -0.002

9b. Ensure that the paste display overlay coincides with the presence of paste. If
this is correct go to Step 20. If this is incorrect, note the position of the
non-existant paste and continue with Step 10.
NOTE
If the paste display overlay coincides with the presence of paste, any poor
inspection results are due to process problems and not 2Di setup.
9c. Ensure that the inspection results are consistent with the amount of paste on
the pad. If this is correct go to Step 20. If this is incorrect continue with
Step 10.
10. Select Exit.
Auto
Scale
Toggle
Paste
Next Previous Save
Image
Exit
11. Select Edit Site.
Edit
Global
Edit
Limits
Delete
Site
Next
Site
Previous
Site
Edit
Site
Inspect
Site
Exit
12. Select Light Setup.
Add
Site
Learn
Site
Light
Setup
Next Previous Incr. Decr. Exit
13. Adjust the lighting parameters to improve the lighting conditions in the
suspect areas.
14. Select Exit.
Record
Image
Next Previous Incr. Decr.
Exit
15. Select Exit.
Add
Site
Learn
Site
Light
Setup
Next Previous Incr. Decr.
Exit
16. Select Exit.
Edit
Global
Edit
Limits
Delete
Site
Next
Site
Previous
Site
Edit
Site
Inspect
Site
Exit
17. Select Step to remove the board from the machine.
Step
Inspect
Setup
Single Exit
Software Version 6 User Manual 8.31
2Di INSPECTION
2Di SETUP