Page 3-17 3 SOLUTIONS FOR ERROR 3 3 444C-E-MMA03-A03-03 Check and Solutions 444C-EEn-MaIc-003 444C-EEn-MaIc-004 444C-EEn-Ma-001 5 . Press Address . 6 . Check the signals. ∗ T urn ON and OFF the sensors to check whether t…

100%1 / 107
Page 3-16
444C-E-MMA03-A03-04
Check and Solutions
444C-EEn-MaSd-001
To the next page
3-2-7 Self-Diagnosis Error
In case of a self-diagnosis error prior to automatic operation, check it.
1. Input and ring load information check
1. Check the error messages.
Pressing Detail displays the factors and
solutions.
(Pressing ESC backs you out of that screen.)
Check the errors displayed on the screen and
recover from them.
E.g.) Are the covers closed properly?
Aren’t there any floating tapes?
Isn’t the Y-axis interfered?
If the causes are not clear, use the following
procedure.
2. Press .
The screen returns to the main menu.
3. Press
Machine
adjust
.
4. Press Input check .
Page 3-17
3
SOLUTIONS FOR ERROR
3
3
444C-E-MMA03-A03-03
Check and Solutions
444C-EEn-MaIc-003
444C-EEn-MaIc-004
444C-EEn-Ma-001
5. Press Address .
6. Check the signals.
Turn ON and OFF the sensors to check
whether the signals of the errors have been
received.
7. Press .
The screen returns to the machine adjustment
menu.
8. Press Ring load information .
9. Check the status.
Check whether the status of the ring load in
use are not NG.
In case of NG, the communication error in the
board, disconnection of the connector, or
contact failure is conceivable.
If you cannot recover from NG in spite of the
power restarting, there is a possibility of board
breakage or contact failure; therefore, contact
us.
If no NG has occurred, check the CPU inter-
lock version from the machine information in
the machine parameter screen and contact us.
Page 3-18
Check and Solutions
444C-E-MMA03-A03-04
3-2-8 Nozzle Setting Error
If a setting error occurs in the nozzle checking operation prior to automatic operation, check it.
1. Checking the details of nozzle checking operation error (With the nozzle changer)
To solve the error occurred in the nozzle
checking operation in starting production, use
the following procedure.
1. Press Yes .
The screen returns to the main menu.
2. Press
Product
config
.
3. Press Nozzle arrangement .
4. Check the nozzles.
Check whether the nozzles that are actually set
are the same as the ones to be used.
5. Press
UNLOCK
+ Nozl set chk .
Recheck whether the registered and the set
nozzles are the same.
If there is no error, go to step 11.
If there is an error, perform steps 6 to 9.
6. Press Measure value .
To the next page
444C-EEn-Ro-003
444C-EEn-Main-004
444C-EOp-Pc-003
1
2