444CEMM2(CM201).pdf - 第62页

Page 3-22 Check and Solutions 444C-E-MMA03-A03-04 T o the next page 4 . Check the nozzles. • Check whether the nozzles that are actually set are the same as the ones to be used. 5 . Press UNLOCK + Nozl set chk . • Rechec…

100%1 / 107
Page 3-21
3
SOLUTIONS FOR ERROR
3
3
Check and Solutions
444C-E-MMA03-A03-04
To the next page
2. Checking the details of nozzle checking operation error (Without the nozzle changer)
To solve the error occurred in the nozzle
checking operation in starting production, use
the following procedure.
1. Press Yes .
The screen returns to the main menu.
2. Press
Product
config
.
3. Press Nozzle arrangement .
Page 3-22
Check and Solutions
444C-E-MMA03-A03-04
To the next page
4. Check the nozzles.
Check whether the nozzles that are actually set
are the same as the ones to be used.
5. Press
UNLOCK
+ Nozl set chk .
Recheck whether the registered and the set
nozzles are the same.
If there is no error, go to step 10.
If there is an error, perform steps 6 to 9.
6. Check the measurement values.
Check the sizes of the registered and the
measured nozzles at the screen.
If some nozzles have not been set or if the
registered nozzle size is different from the
measured one, an error occurs and the mes-
sage appears.
Press OK .
7. Press Recog scrn .
Page 3-23
3
SOLUTIONS FOR ERROR
3
3
Check and Solutions
444C-E-MMA03-A03-04
444C-EEn-PcNa-013
The whole and the individual nozzle recogni-
tion image can be checked.
[Possible factors]
Nozzle setting mistake
Foreign bodies on the nozzle tip
Chipped nozzle tip
Deformation of the nozzle
Contamination of the reflector
Contamination of the LED cover
Contamination of the camera lens
[Solutions]
Cleaning the nozzle, reflector, camera lens,
and cover lens
Replacing the nozzle
8. Press .
9. After solving the error, press
UNLOCK
+ Nozl set chk .
The message Nozzle is set correctly. ap-
pears.
10. Press OK .
Resume the production.