444CEMM2(CM201).pdf - 第59页

Page 3-19 3 SOLUTIONS FOR ERROR 3 3 Check and Solutions 444C-E-MMA03-A03-03 T o the next page • Check the sizes of the registered and the measured nozzles at the screen. 7 . Press ESC and then UNLOCK + Nozl set chk . • I…

100%1 / 107
Page 3-18
Check and Solutions
444C-E-MMA03-A03-04
3-2-8 Nozzle Setting Error
If a setting error occurs in the nozzle checking operation prior to automatic operation, check it.
1. Checking the details of nozzle checking operation error (With the nozzle changer)
To solve the error occurred in the nozzle
checking operation in starting production, use
the following procedure.
1. Press Yes .
The screen returns to the main menu.
2. Press
Product
config
.
3. Press Nozzle arrangement .
4. Check the nozzles.
Check whether the nozzles that are actually set
are the same as the ones to be used.
5. Press
UNLOCK
+ Nozl set chk .
Recheck whether the registered and the set
nozzles are the same.
If there is no error, go to step 11.
If there is an error, perform steps 6 to 9.
6. Press Measure value .
To the next page
444C-EEn-Ro-003
444C-EEn-Main-004
444C-EOp-Pc-003
1
2
Page 3-19
3
SOLUTIONS FOR ERROR
3
3
Check and Solutions
444C-E-MMA03-A03-03
To the next page
Check the sizes of the registered and the
measured nozzles at the screen.
7. Press ESC and then
UNLOCK
+ Nozl set chk .
If some nozzles have not been set or if the
registered nozzle size is different from the
measured one, an error occurs and the mes-
sage appears.
Press OK .
8. Press Recog scrn .
The whole and the individual nozzle recogni-
tion image can be checked.
[Possible factors]
Nozzle setting mistake
Foreign bodies on the nozzle tip
Chipped nozzle tip
Deformation of the nozzle
Contamination of the reflector
Contamination of the LED cover
Contamination of the camera lens
[Solutions]
Cleaning the nozzle, reflector, camera lens,
and cover lens
Replacing the nozzle
Page 3-20
Check and Solutions
444C-E-MMA03-A03-04
444C-EEn-PcNa-013
9. Press .
10. After solving the error, press
UNLOCK
+ Nozl set chk .
The message Nozzle is set correctly. ap-
pears.
11. Press OK .
Resume the production.