2 Safety 2.2 Warning labels 18 User Manual SIPLACE Head Care Station 10/2017 2.2.3 Warning labels on the SIPLACE MultiStar CPP / CPP M Fig.10: Warning labels on the SIPLACE MultiStar CPP / CPP M 1 Item W laser class 2 […

2 Safety
2.2 Warning labels
User Manual SIPLACE Head Care Station 10/2017 17
2.2.2 Warning labels on the SIPLACE SpeedStar C&P20 P / C&P20 M2
Fig.8: Warning labels on the SIPLACE SpeedStar C&P20 P / C&P20 M2
1 Temperature label [03031926-xx] 2 Item W laser class 2 [03134118-xx]
2.2.2.1 High temperatures on the SIPLACE C&P20 P / C&P20 M2
High temperatures on the SIPLACE C&P20 P / C&P20 M2 during
continuous operation
Risk of burns due to high temperatures!
The housing of the star motor and the handle on the placement head may
become very hot during continuous operation and if the ambient temperature
is greater than 22°.
→ Be careful when touching the parts.
Item no.: 03031926-xx
Quantity per head: 1
2.2.2.2 Laser class 2 on the component sensor
Fig.9: Laser class 2
Laser class 2
The laser classes are determined according to
IEC60825-1:2014.
Item no.: 03134118-xx
Quantity per head: 1
→ Do not look into beam!

2 Safety
2.2 Warning labels
18 User Manual SIPLACE Head Care Station 10/2017
2.2.3 Warning labels on the SIPLACE MultiStar CPP / CPP M
Fig.10: Warning labels on the SIPLACE MultiStar CPP / CPP M
1 Item W laser class 2 [03134118-xx] 2 Temperature label [03031926-xx]
2.2.3.1 High Temperatures on the SIPLACE CPP / CPP M
High temperatures on the SIPLACE CPP / CPP M during continuous op-
eration
Risk of burns due to high temperatures!
The Z drive (linear motor) can develop high surface temperatures during
continuous operation if the ambient temperature is greater than 22°C.
→ Be careful when touching the parts.
Item no.: 03031926-xx
Quantity per head: 1
2.2.3.2 Laser class 2 on the component sensor
Fig.11: Laser class 2
Laser class 2
The laser classes are determined according to
IEC60825-1:2014.
Item no.: 03134118-xx
Quantity per head: 1
→ Do not look into beam!

2 Safety
2.3 Safety instructions for the power supply
User Manual SIPLACE Head Care Station 10/2017 19
2.3 Safety instructions for the power supply
WARNING
Some parts of the system carry potentially lethal voltages
The machine is supplied with 1/N/PE 100V~ to 240V~, 50/60Hz mains voltage. This
means that some parts of the system carry potentially lethal voltages - even when switched
off at the main power switch. Incorrect handling of the head care station can therefore result
in death or severe injury or considerable damage to equipment.
► Always follow the applicable accident prevention and safety regulations (particularly
DIN EN 60204, part 1 or IEC 60204, part 1) and the safety regulations in your own
country.
●
This means that some parts of the system carry potentially lethal voltages – even when
switched off at the main power switch.
●
Incorrect handling of the HCS can therefore result in fatal injuries, severe injuries or consider-
able damage to equipment.
●
Measurements and maintenance work must always be carried out by appropriately qualified
personnel.
●
Always follow the applicable accident prevention and DIN regulations (particularly DIN EN 60
204, part 1) or the regulations specific to your country.
●
Before starting any maintenance work, switch the HCS off at the main switch and disconnect it
from the main power supply.
●
Always secure the HCS against unauthorized reactivation. If these instructions are not fol-
lowed, you may be able to touch live parts, which could result in fatal or severe injuries.
Maintaining, installing or removing assemblies
► End all verification operations at the HCS.
► Close the SIPLACE Test Bench software.
► Shut down the Windows operating system correctly, otherwise problems may occur when re-
starting or data may be lost.
► Switch off the HCS at the main switch.
► Disconnect the HCS from the main power supply.