User Manual SIPLACE Head Care Station -.pdf - 第59页
5 Working with the HCS 5.2 Head verification process User Manual SIPLACE Head Care Station 10/2017 59 Fig.56: Inserting the stopper ► Insert the correct stopper (1) . NOTICE! The tool clamping(2) has two different v…

5 Working with the HCS
5.2 Head verification process
58 User Manual SIPLACE Head Care Station 10/2017
Fig.54: Adjustment wheel and manometer
► Pull off the cap(1) of the adjustment wheel.
► Turn the adjustment wheel until the mano-
meter(2) shows 4.8 bar.
5.2.1.2 Setting up a P&P module
Fig.55: P&P module
1 Hose for compressed air supply to head 2 Exhaust air hose
3 Hose for compressed air supply to PRV 4 Stopper for P&P modules
5 Placement head with calibration nozzles 6 Flat ribbon cable connecting head inter-
face and head adapter
7 Flat ribbon cable to the head interface
NOTICE
Calibration nozzle
For the head verification, the head must be equipped with calibration nozzles.

5 Working with the HCS
5.2 Head verification process
User Manual SIPLACE Head Care Station 10/2017 59
Fig.56: Inserting the stopper
► Insert the correct stopper(1).
NOTICE!
The tool clamping(2) has two different ver-
sions: The new tool locking using a spring,
the former tool locking using a screw.
.
Fig.57: Mounting the head
► Fasten the screws to the head mounting
board(1) with a torque of 2.7Nm.
NOTICE!
The screw holes to be used for the various
heads are indicated on the board.
Thread missing! The screw at the right bottom
cannot be fixed as the mounting board is not
provided with the corresponding thread.
.
Fig.58: Connecting the cables
Connections at the front:
► Connect the flat ribbon cable(2) to the board ad-
apter head interface(1).

5 Working with the HCS
5.2 Head verification process
60 User Manual SIPLACE Head Care Station 10/2017
Fig.59: Removing the cover
Connections at the back:
► Grab the knob(1) and pull the protective
cover(2) with the actuator(3) upwards out of the
safety switch(4).
Fig.60: Connecting the flat ribbon cables
► Connect the flat ribbon cables(2) of the Board
Adapter-LP C700B-HCSII[03087842-xx] to the
Board Adapter-LP DLM4/TWIN-HC-
SII[03087844-xx](1).
► Fit the cover back on.
► Make sure that the actuator snaps back into the
safety switch(3).
Fig.61: Connecting the hoses
► Connect the hose for the exhaust air to the
head (1).
► Connect the hose for compressed air supply to
the head top(2).
► Connect the hose for compressed air supply to
the pressure regulator valve (PRV)(3).
For information on the correct pneumatic connections,
see 3.1.6.2 "Pneumatic connections for the
heads" [}41].