5 Working with the HCS
5.2 Head verification process
User Manual SIPLACE Head Care Station 10/2017 63
5.2.3.1 Test Bench Start screen
When the SIPLACE software is started, the following screen is displayed:
Fig.66: Test Bench Start screen
5.2.3.2 First start of software
The vacuum system and the CAN-Bus setup might not be automatically detected. If this is the
case, both need to be configured manually.
Fig.67: Machine configuration
Log on as machine service. 5.2.4 "Changing the
user role" [}64]
Click the Automatically update and configure
the machine icon(1).
Click the Confirm automatically detected
machine configuration like camera type, con-
veyor type… icon(2).
Click Edit…(3).
Fig.68: Vacuum type selection
Select the Vacuum type.
Wrong vacuum values
The selection applies the vacuum limits to be
used for the verification. If the vacuum type does
not match the connected vacuum supply, wrong
results will be provided.
Click Save new configuration and continue
startup.
5 Working with the HCS
5.2 Head verification process
64 User Manual SIPLACE Head Care Station 10/2017
5.2.4 Changing the user role
You are currently logged on as operator. To enable more settings we recommend to switch to
machine service:
Fig.69: Machine service role
Click the Set settings and options, conveyor
interface, shutdown icon(1).
Click the Check and set user settings icon(2).
Select Machine service(3).
ð The user role has been changed to machine
service providing additional functionalities.
5.2.5 Check / adjust the force sensor reference voltage
The force sensor is a shock-sensitive device and easily loses the adjusted reference voltage which
can lead to values not being captured during the measurement.
To avoid the risk of losing values during the force measurement, it is recommended to check the
force sensor beforehand and adjust it if necessary.
Fig.70: Force measurement unit
Connect the force measurement unit
[03086502](1) to the external Force sensor con-
nector(2).
Have a watchmakers screw driver within reach
which is compatible with the force sensor
screw(3).
5 Working with the HCS
5.2 Head verification process
User Manual SIPLACE Head Care Station 10/2017 65
Fig.71: TEST: Force sensor reference voltage 20N function
Click the Test bench service icon(3).
Open the Force Measurement menu(1).
Select the TEST: Force sensor reference
voltage 20N function(2).
Click the Start button(4).
ð The Reference voltage is displayed and a
countdown during which the force sensor can
be adjusted.
Fig.72: Reference voltage and countdown
Check the displayed Reference voltage.
Fig.73: Force sensor screw
Turn the force sensor screw(1) until you reached
a value between +/-10mV.
If the time has elapsed and the value is still out-
side +/-10mV, click Retry and adjust the force
sensor again.
Remove the force measurement unit from the
head unit.
Click the Cancel button.
NOTICE
Adjusting the force sensor is only necessary for the first head verification process.
After that, the adjusted value is saved for all subsequent measurements.