5 Working with the HCS
5.2 Head verification process
62 User Manual SIPLACE Head Care Station 10/2017
5.2.3 Starting the HCS software
► On the desktop, double-click the TB Start icon to start the verification software:
ð The HCS Startup screen is displayed:
Fig.65: HCS Startup screen
If the head was initialized correctly, the head is automatically detected and selected under Head-
configuration.
NOTICE
No head detected
If the head initialization failed, no head can be detected. Manual head selection is selec-
ted
under Settings. Not supported is selected under Head configuration.
Autostart option
If the Autostart option is enabled, the software starts automatically within seconds. See 5.2.3.1
"Test Bench Start screen" [}63].
Manual head selection
If the Manual head selection option is enabled, heads need to be selected manually before start-
ing the SIPLACE Test Bench.

5 Working with the HCS
5.2 Head verification process
User Manual SIPLACE Head Care Station 10/2017 63
5.2.3.1 Test Bench Start screen
When the SIPLACE software is started, the following screen is displayed:
Fig.66: Test Bench Start screen
5.2.3.2 First start of software
The vacuum system and the CAN-Bus setup might not be automatically detected. If this is the
case, both need to be configured manually.
Fig.67: Machine configuration
► Log on as machine service. 5.2.4 "Changing the
user role" [}64]
► Click the Automatically update and configure
the machine icon(1).
► Click the Confirm automatically detected
machine configuration like camera type, con-
veyor type… icon(2).
► Click Edit…(3).
Fig.68: Vacuum type selection
► Select the Vacuum type.
► Wrong vacuum values
The selection applies the vacuum limits to be
used for the verification. If the vacuum type does
not match the connected vacuum supply, wrong
results will be provided.
► Click Save new configuration and continue
startup.

5 Working with the HCS
5.2 Head verification process
64 User Manual SIPLACE Head Care Station 10/2017
5.2.4 Changing the user role
You are currently logged on as operator. To enable more settings we recommend to switch to
machine service:
Fig.69: Machine service role
► Click the Set settings and options, conveyor
interface, shutdown icon(1).
► Click the Check and set user settings icon(2).
► Select Machine service(3).
ð The user role has been changed to machine
service providing additional functionalities.
5.2.5 Check / adjust the force sensor reference voltage
The force sensor is a shock-sensitive device and easily loses the adjusted reference voltage which
can lead to values not being captured during the measurement.
To avoid the risk of losing values during the force measurement, it is recommended to check the
force sensor beforehand and adjust it if necessary.
Fig.70: Force measurement unit
► Connect the force measurement unit
[03086502](1) to the external Force sensor con-
nector(2).
► Have a watchmakers screw driver within reach
which is compatible with the force sensor
screw(3).