(7) When the compared data is not identical, a warning peep sounds twice and “<NG>” appears on the bottom right of “READ ID” and “<MISMA TCH>” on the bottom left of the window . (Fig. 13) Fig. 13 When the [EN…

(2) A peep sounds when the bar code is read successfully.
(3) When the reader fails in reading the bar code, “<?>” appears on the
bottom right of “READ ID”. (Fig. 11)
Fig. 11
(4) When the reader fails in reading the bar code by all means, press
the [ENT] key to open the “** BC INPUT **” window (Fig. 14) for
manual entry of the feeder No.
(5) When the bar code is read successfully, the read feeder No. is com-
pared with the specified one.
(6) When the read feeder No. coincides with the specified one, “<OK>”
appears on the bottom right of “READ ID”. (Fig. 12)
After “<OK>” has appeared for a certain period of time, the feeder
No. (FDR NO.) and the component name (ID) to be checked sub-
sequently are displayed.
After the components of all feeders are checked completely, the
system is shifted to the “7.3.4 Result Response” session.
Fig. 12
021 1-001 1 8
AIH01EGP
** CUR. CHECK **
FDR NO.>999
READ ID XXXXXXXXXXXX
XXXXXXXXXXXX
<?>
7.3 Checking the Components for the Current and Next Programs
** CUR. CHECK **
FDR NO.>999
READ ID XXXXXXXXXXXX
XXXXXXXXXXXX
<OK>

(7) When the compared data is not identical, a warning peep sounds
twice and “<NG>” appears on the bottom right of “READ ID” and
“<MISMATCH>” on the bottom left of the window. (Fig. 13)
Fig. 13
When the [ENT] key is pressed subsequently, the “** BC INPUT **”
window (Fig. 14) appears for manual entry of the feeder No.
Fig. 14
(8) Enter the feeder No. where the tape feeder should be set and press
the [ENT] key.
(9) The entered feeder No. is compared with the specified one.
(10) When the entered feeder No. coincides with the specified one,
“<OK>” appears on the bottom right of “READ ID”.
After “<OK>” has appeared for a certain period of time, the feeder
No. (FDR NO.) and the component name (ID) to be checked sub-
sequently are displayed.
After the components of all feeders are checked completely, the
system is shifted to the “7.3.4 Result Response” session.
(11) When the entered feeder No. does not coincide with the specified
one, a warning peep sounds twice and “<NG>” appears on the
bottom right of “READ ID”.
Then, the “** CUR. CHECK **” window (Fig. 10) resumes.
021 1-001 1 9
AIH01EGP
7.3 Checking the Components for the Current and Next Programs
** CUR. CHECK **
FDR NO.>999
READ ID XXXXXXXXXXXX
XXXXXXXXXXXX
<NG>
<MISMATCH> HIT ENT
** BC INPUT **
FDR NO.>
READ ID XXXXXXXXXXXX
XXXXXXXXXXXX
<NG>
<MISMATCH>

7.3.3 Entering the component name (ID) manually
When the reader fails in reading the bar code or the expected result is
not obtained, the component name (ID) can be entered manually.
Shown below is the window which enables you to enter the component
name (ID) manually.
Fig. 15
(1) To enter an alphabet letter, use the appropriate function key ([F1]
through [F4]) and press the corresponding numeric key. (Combina-
tion of Function and Numeric Keys)
Refer to “13. Table of Key Codes” for details.
Available characters are alphabet letters (capital letters), numbers,
$, %, /, :, ,, *, +, -, ., and space.
(2) After the component name (ID) is entered, press the [ENT] key.
When the entered component name (ID) is correct, the window (Fig.
16) appears on the screen.
After the window has appeared for a certain period of time, the feeder
No. (FDR NO.) and the component name (ID) to be checked sub-
sequently are displayed.
After the components of all feeders are checked completely, the
system is shifted to the “7.3.4 Result Response” session.
Fig. 16
021 1-001 2 0
AIH01EGP
7.3 Checking the Components for the Current and Next Programs
** BC INPUT **
FDR NO. 999
INPT ID
<NG>
<MISMATCH>
** BC INPUT **
FDR NO. 999
INPT ID XXXXXXXXXXXX
XXXXXXXXXXXX
<OK>