SOM-1617-001.pdf - 第32页

8.2 Confirmation of Operation When the [F1], the [F2], or the [F3] key is pressed, the following window appears, prompting the confirmation to the selected operation. Fig. 35 When the [F1] (YES) key is pressed, the selec…

100%1 / 45
8. Data Operation
8. Data Operation
When “3. OPERATE” is selected at the “** MAIN MENU **” window
(Fig. 4), the following window appears on the screen.
Fig. 34
[Displayed Contents]
SWAP : Select this label to replace the component list of the current
program (current product’s program) stored in the bar code
reader with the list of the next program (next-term product’s
program). This function should be used when a program
change operation is performed.
CLR1 : Select this label to clear the component list of the current
program stored in the bar code reader.
It is required to clear the list once when all feeders of the
current program are checked.
CLR2 : Select this label to clear the component list of the next pro-
gram stored in the bar code reader. It is required to clear
the list once when all feeders of the next program are
checked.
FDR : Select this label to set “ON” or “OFF” for “FDR CHECK ?”
when the feeder No. (FDR NO.) should also be checked
with the component and the actual objects (Nos. of the cur-
rently selected and newly prepared feeders) are collated.
8.1 Operation
(1) When the [F1] (SWAP) key is pressed, the ID list of the current
program (current product’s program) is replaced with the ID list of
the next program (next-term product’s program).
(2) When the [F2] (CLR1) key is pressed, the ID list of the current pro-
gram is cleared.
(3) When the [F3] (CLR2) key is pressed, the ID list of the next program
is cleared.
(4) When the [F4] (FDR) key is pressed, it is determined whether or not
the selected feeder No. should be checked.
0211-001 30
AIH01EGP
** DATA OPERATION **
SWAP CLR1 CLR2 FDR
8.2 Confirmation of Operation
When the [F1], the [F2], or the [F3] key is pressed, the following window
appears, prompting the confirmation to the selected operation.
Fig. 35
When the [F1] (YES) key is pressed, the selected function is imple-
mented. After that, the “** MAIN MENU **” window (Fig. 4) resumes.
When the [F3] (NO) key is pressed, the selected function is interrupted
and the “** MAIN MENU **” window resumes.
8.3 Setting of Confirmation to Feeder No. and Check-
ing on Collation of Actual Component Names
When the [F4] key is pressed, the following window appears on the
screen, enabling you to determine whether or not the feeder No. should
be checked.
Fig. 36
When the [F1] (ON) key is pressed, it is determined that the feeder No.
should be checked. As a result, the feeder No. is checked after the com-
ponent ID.
When the [F3] (OFF) key is pressed, it is determined that the feeder No.
should not be checked. As a result, only the component ID is checked.
0211-001 31
AIH01EGP
** DATA OPERATION **
ARE YOU SURE ?
YES NO
** DATA OPERATION **
FDR CHECK ?
ON OFF
8.2 Confirmation of Operation
To check the feeder No., the printed bar code label (feeder
No.) is required.
When the [F1] (ON) or the [F3] (OFF) key is pressed, the window
(Fig. 37) appears on the screen, enabling you to determine whether or
not the actual objects should be collated.
Fig. 37
When the [F1] (ON) key is pressed, it is determined that the actual ob-
jects should be collated.
When the [F3] (OFF) key is pressed, it is determined that the actual
objects should not be collated.
The actual object collation function is valid only when the feeder
is empty of components.
When the [F1] (ON) or the [F3] (OFF) key is pressed, the “** MAIN MENU
**” window (Fig. 4) resumes.
0211-001 32 AIH01EGP
** DATA OPERATION **
SAME CHECK ?
ON OFF
8.2 Confirmation of Operation