(3) When the entered component name (ID) is not correct, a warning peep sounds twice and the window (Fig. 17) appears on the screen. When the [ENT] key is pressed, the window (Fig. 15) resumes. Fig. 17 7.3.4 Result Respo…

100%1 / 45
7.3.3 Entering the component name (ID) manually
When the reader fails in reading the bar code or the expected result is
not obtained, the component name (ID) can be entered manually.
Shown below is the window which enables you to enter the component
name (ID) manually.
Fig. 15
(1) To enter an alphabet letter, use the appropriate function key ([F1]
through [F4]) and press the corresponding numeric key. (Combina-
tion of Function and Numeric Keys)
Refer to “13. Table of Key Codes” for details.
Available characters are alphabet letters (capital letters), numbers,
$, %, /, :, ,, *, +, -, ., and space.
(2) After the component name (ID) is entered, press the [ENT] key.
When the entered component name (ID) is correct, the window (Fig.
16) appears on the screen.
After the window has appeared for a certain period of time, the feeder
No. (FDR NO.) and the component name (ID) to be checked sub-
sequently are displayed.
After the components of all feeders are checked completely, the
system is shifted to the “7.3.4 Result Response” session.
Fig. 16
021 1-001 2 0
AIH01EGP
7.3 Checking the Components for the Current and Next Programs
** BC INPUT **
FDR NO. 999
INPT ID
<NG>
<MISMATCH>
** BC INPUT **
FDR NO. 999
INPT ID XXXXXXXXXXXX
XXXXXXXXXXXX
<OK>
(3) When the entered component name (ID) is not correct, a warning
peep sounds twice and the window (Fig. 17) appears on the screen.
When the [ENT] key is pressed, the window (Fig. 15) resumes.
Fig. 17
7.3.4 Result Response
When all feeders are checked completely or the [F4 (EXIT)] key is
pressed, the following window appears on the screen.
Fig. 18
(1) When the [F3] (NO) key is pressed, the feeders can be re-checked,
starting with the first one.
Once a feeder is checked, the result is kept valid.
021 1-001 2 1
AIH01EGP
** BC INPUT **
FDR NO. 999
INPT ID XXXXXXXXXXXX
XXXXXXXXXXXX
<NG>
<INPUT ERROR> HIT ENT
7.3 Checking the Components for the Current and Next Programs
** CUR. CHECK **
FDR NO. 999
READ ID XXXXXXXXXXXX
XXXXXXXXXXXX
<CHECK COMPLETE>
YES NO
(2) When the [F1] (YES) key is pressed, the window (Fig. 19) appears
on the screen.
When this key is pressed, the bar code reader must be set on
the communication adapter.
Fig. 19
(3) When the [ENT] key is pressed, the result of the feeder checking is
sent to the machine. (Fig. 20) After that, the “** MAIN MENU **”
window (Fig. 4) resumes.
When no response is received from the machine, the session
is terminated forcibly in about 10 seconds.
Fig. 20
(4) When the bar code reader is not set on the communication adapter
in Step (2), the window (Fig. 21) appears on the screen.
Set the bar code reader on the communication adapter and press
the [ENT] key.
Fig. 21
021 1-001 2 2
AIH01EGP
7.3 Checking the Components for the Current and Next Programs
** RESULT OUT **
-- HIT ENT KEY --
** RESULT OUT **
.....
** RESULT OUT **
SET ON ADAPTOR
READY : HIT ENT KEY