(8) Enter the feeder No. of the tape feeder that caused a component shortage error and press the [ENT] key . (9) The entered feeder No. is compared with the specified one. (10) When the compared data is identical, “<O…

100%1 / 45
(6) When the compared data coincides with the specified one, “<OK>”
appears on the bottom right of “READ ID”. (Fig. 28)
After the window has appeared for a certain period of time, the feeder
No. (FDR NO.) and the component name (ID) to be checked sub-
sequently are displayed.
After the components of all feeders are checked completely, the
system is shifted to the “7.3.4 Result Response” session.
Fig. 28
(7) When the compared data is not identical, a warning peep sounds
twice and “<NG>” appears on the bottom right of “READ ID” and
“<MISMATCH>” on the bottom left of the window. (Fig. 29)
Fig. 29
When the [ENT] key is pressed subsequently, the “** BC INPUT **”
window (Fig. 30) appears for manual entry of the feeder No.
Fig. 30
021 1-001 2 7
AIH01EGP
** COMP EMPTY **
EMPTY FDR NO.>999
READ ID XXXXXXXXXXXX
XXXXXXXXXXXX
<OK>
** COMP EMPTY **
EMPTY FDR NO.>999
READ ID XXXXXXXXXXXX
XXXXXXXXXXXX
<NG>
<MISMATCH> HIT ENT
** BC INPUT **
FDR NO.>
READ ID XXXXXXXXXXXX
XXXXXXXXXXXX
<NG>
<MISMATCH>
7.3 Checking the Components for the Current and Next Programs
(8) Enter the feeder No. of the tape feeder that caused a component
shortage error and press the [ENT] key.
(9) The entered feeder No. is compared with the specified one.
(10) When the compared data is identical, “<OK>” appears on the bot-
tom right of “READ ID”.
After the window has appeared for a certain period of time, the
feeder No. (FDR NO.) and the component name (ID) to be checked
subsequently are displayed.
After the components of all feeders are checked completely, the
system is shifted to the “7.3.4 Result Response” session.
(11) When the compared data is not identical, a warning peep sounds
twice and “<NG>” appears on the bottom right of “READ ID” and
the window (Fig. 10) resumes, enabling the checking of the feeder
No.
7.3.9 Entering the name (ID) of the component manually that
caused a component shortage error
When the reader fails in reading the bar code or the expected result is
not obtained, the component name (ID) can be entered manually.
Shown below is the window which enables you to enter the component
name (ID) manually.
Fig. 31
(1) To enter an alphabet letter, use the appropriate function key ([F1]
through [F4]) and press the corresponding numeric key. (Combina-
tion of Function and Numeric Keys)
Refer to “13. Table of Key Codes” for details.
Available characters are alphabet letters (capital letters), numbers,
$, %, /, :, ,, *, +, -, ., and space.
021 1-001 2 8
AIH01EGP
** BC IPUT **
EMPTY FDR NO. 999
INPT ID
<NG>
<MISMATCH>
7.3 Checking the Components for the Current and Next Programs
(2) After the component name (ID) is entered, press the [ENT] key.
When the entered component name (ID) is correct, the window
(Fig. 32) appears on the screen.
After the window has appeared for a certain period of time, the feeder
No. (FDR NO.) and the component name (ID) to be checked sub-
sequently are displayed.
After the components of all feeders are checked completely, the
system is shifted to the “7.3.4 Result Response” session.
Fig. 32
(3) When the entered component name (ID) is not correct, a warning
peep sounds twice and the window (Fig. 33) appears on the screen.
When the [ENT] key is pressed, the window (Fig. 26) resumes, en-
abling you to manually enter the name (ID) of the component that
caused a component shortage error.
Fig. 33
** BC INPUT **
EMPTY FDR NO. 999
INPT ID XXXXXXXXXXXX
XXXXXXXXXXXX
<OK>
** COMP EMPTY **
EMPTY FDR NO. 999
INPT ID XXXXXXXXXXXX
XXXXXXXXXXXX
<NG>
<INPUT ERROR>HIT ENT