SOM-1617-001.pdf - 第6页

1. Scope 021 1-001 5 AIH01EGP 1. Scope This specially specified function is used with the bar code reader and determines whether or not the correct components are loaded onto the machine when the tape feeders are install…

100%1 / 45
Contents
Page
7.3.8 Checking the feeder No. that
caused a component shortage error
....................
....................
.......... 25
7.3.9 Entering the name (ID) of the component manually
that caused a component shortage error
..............
..............
....... 28
8. Data Operation
........................................................................
........................................................................
.................................... 30
8.1 Operation
............................................................................
............................................................................
...................................... 30
8.2 Confirmation of Operation
..................................................
..................................................
......................... 31
8.3 Setting of Confirmation to Feeder No. and
Checking on Collation of Actual Component Names
....
....
.. 31
9. Setting the Number of Bar Code Digits
..................................
..................................
................. 33
9.1 Operation
............................................................................
............................................................................
...................................... 33
10. Masking the Component Name (ID) to be Checked
..............
..............
....... 34
10.1 Operation
..........................................................................
..........................................................................
..................................... 34
11. Program Setup
......................................................................
......................................................................
................................... 36
12. Process Flow
..........................................................................
..........................................................................
..................................... 37
13. Table of Key Codes
................................................................
................................................................
................................ 38
14. Materials
................................................................................
................................................................................
........................................ 39
Layout of Panel 3
..................................................................
..................................................................
................................. 39
Layout of Control P.C.B.
........................................................
........................................................
............................ 40
Power Circuit Diagram (2)
....................................................
....................................................
.......................... 41
Feeder Checker Connection Diagram
..................................
..................................
................. 42
021 1-001 4 AIH01EGP
1. Scope
021 1-001 5 AIH01EGP
1. Scope
This specially specified function is used with the bar code reader and
determines whether or not the correct components are loaded onto the
machine when the tape feeders are installed on the feeder carriage or
the components are prepared beforehand, preventing wrong installation
of feeders.
2. Function
Current Program Component Check Function
When the feeders loaded with components are installed on the feeder
carriage, this function checks whether the loaded components are
correctly selected in compliance with the current pattern program data
(pattern program data selected for the current production model).
The machine cannot be started unless the feeder check operation is
completed.
Next Program Component Pre-Check Function
This function pre-checks the components scheduled to be used in the
pattern program data for the next program, making it possible to start
the operation of the machine without checking the components after
the next program is set up in the “PROGRAM CHANGE” tab sheet.
Replenishment Component Check Function
This function checks whether or not the feeders are replenished with
correct components after a component shortage error has occurred.
(a) It is also possible to invalidate these functions.
(b) Types of Readable Bar Codes
· JAN Code
· NW7 Code
· CODE39 Code
· ITF Code
3. Monitor on Machine Side
3.1 “Feeder Checker Set-up” Window
When the [Next] key (*1) is pressed in the “Opn.Mode” tab sheet, the
following sheet appears on the screen.
“Enable” or “Disable” can be selected in the “Feeder Checker Set-up”
group box.
Fig. 1 “Opn. Mode” Tab Sheet
*2 Feeder Checker Set-up
[Enable] Button : Automatic operation cannot be started unless
the feeder check operation is completed.
[Disable] Button : Automatic operation can be started regard-
less of the feeder check function.
*3 Output Data
[Shortage] Button : When a component shortage error is de-
tected, the check data is transmitted to the
bar code reader.
When components for which a component
shortage error cannot be detected are used
and a component missing error is detected
during pick-up sequence, the check data is
transmitted to the bar code reader.
[All Missing] Button : When no component is picked up (all com-
ponents missing), the data check is trans-
mitted to the bar code reader regardless of
whether or not the tape end detection is used.
021 1-001 6
AIH01EGP
*2
*3
*4
*5
*1
*7
*6
3. Monitor on Machine Side