Installation Trace Host and Trace Service
Installation Trace Host
Installation Manual SIPLACE Traceability 3.1
39
X Before SIPLACE Explorer Traceability can be installed, you must have SIPLACE Trace Host and
SIPLACE Explorer installed on your system. If both of these applications are already installed,
installation of SIPLACE Explorer Traceability will begin automatically. SIPLACE Explorer
Traceability must be installed on the same computer as SIPLACE Explorer, SIPLACE Trace Host
can be installed on a different computer.
X If the SIPLACE Explorer Traceability installation procedure is unable to locate SIPLACE Explorer on
your computer, you will see the following dialog box.
X Specify the SIPLACE Explorer installation folder here. If SIPLACE Explorer has not yet been
installed on your computer, you can click on Cancel to terminate the SIPLACE Explorer Traceability
installation procedure.
X Install SIPLACE Trace Host and SIPLACE Explorer on your computer and then restart the SIPLACE
Traceability installation procedure.
X If SIPLACE Trace Host and SIPLACE Explorer are already installed on your system, the installation
procedure will continue.
X Read the license conditions. Click on I accept ... to accept and on I do not accept ... if you do not
want to accept. If you click on I do not accept ..., the installation procedure will be terminated.
X The following dialog box will be shown:
Installation Trace Host and Trace Service
Trace Host Installation
40 Installation Manual SIPLACE Traceability 3.1
X Click on the Install button to start the actual installation of SIPLACE Explorer Traceability.
X Once the installation procedure has finished, the following dialog box will open:
X Click on Finish. The SIPLACE Explorer Traceability option is now available on the SIPLACE
Explorer factory website.
Installation Trace Host and Trace Service
Steps to Perform After Installation Trace Host
Installation Manual SIPLACE Traceability 3.1
41
5.4.2 Steps to Perform After Installation
5.4.3 Troubleshooting
5.4.3.1 Port Configuration after Changing Tomcat Port Number
The Tomcat port number needs to be changed (as described below) in the following cases:
If the port is changed for website generation, in the Trace Host Manager, General tab.
If the standard port number 8080 is already in use and you do not want to use it again for this job
(website access).
X To change the port number, find the following lines in the file
<Tomcat-location>\conf\server.xml
X and change 8080 to your choice of port number as shown below:
<!-- Define a non-SSL Coyote HTTP/1.1 connector on the port specified during installation-->
<Connector port="8080" maxThreads="150" minSpareThreads="25" maxSpareThreads="75"
enableLookups="false" redirectPort="8443" acceptCount="100" debug="0"
connectionTimeout="20000" disableUploadTimeout="true" />
X Change the specified port number 8080 (
Connector port="8080"
) to the required port number
(
Connector port="YourPort"
). For further information about port number, please contact your
system administrator.
X To make Tomcat your default web server, set the port number to 8080.
5.4.3.2 Collation Conflicts When Restoring Database Backup
When restoring the database backup, the SQL Server must have the same collation as the database
backup. Otherwise run time errors and collation conflicts will occur when performing data query in Trace
Host Monitor.
X In case of collation conflicts we recommend you to recreate the SQL Server.
NOTE:
By default, Tomcat is installed on port 8080. This means that your users will access your website
as follows: http://yourServerName:8080/yourWebsite.
NOTE:
The port number specified in this xml file needs to be added to the URL address each time you
generate a website: http://yourServerName:yourPort/yourWebsite.